680 Synergy Plus – Digital Weight Indicator
11.3.3 Avery Weigh-Tronix Stream Format (wtronix)
<SP>
<G/N>
Space
g for Gross
n for Net
Six digits, right justified, floating decimal,
leading zeros are present
11.3.4 Mettler Toledo Stream Format (toledo)
<STX>
<SWA>
STX (02h)
Status Word A
Six digits, right justified, dummy zeros, decimal
point with no leading zeroes except for immediately
preceding the decimal point. Leading zeroes
transmitted as spaces.
Status Word A:
7
6
5
Parity
0
1
MUL1 MUL0
Even parity bit.
Requires EDP Port setup.
Disp. Div.
MUL1 MUL0 Multiplier
0 1 x 1
1 0 x 2
1 1 x 5
Status Word B:
7
6
5
Parity
0
1
Even parity bit:
Requires EDP Port
setup.
0 = lb
1 = kg
64
Visit our website
<POL>
<wwwwww>
Polarity:
<+> for positive
"–" for negative
Figure 11-3. Avery Weigh-Tronix Stream Data Format
<SWB>
<SWC>
<wwwwww>
Status Word B
Status Word C
4
3
2
1
0
DP2 DP1
DP0
DP2 DP1 DP0 Fixed Zero/Dec. Pt. Location
0 0 0 x 100
(2 fixed zeroes)
0 0 1 x 10
(1 fixed zero)
0 1 0 x 1
(No decimal point)
0 1 1 x 0.1
(1 decimal place)
1 0 0 x 0.01
(2 decimal places)
1 0 1 x 0.001
(3 decimal places)
1 1 0 x 0.0001 (4 decimal places)
1 1 1 x 0.00001 (5 decimal places)
4
3
2
1
0
0 = Positive indicated weight value
1 = Negative indicated weight value
0 = In range
1 = Out of range
0 = Stable
1 = Motion
Figure 11-4. Mettler Toledo Stream Data Format
www.RiceLake.com
<SP>
Space
lb = pound
kg = kilogram
g = gram
tn = ton (short)
t = ton (metric)
oz = ounce
<space> = none
<tttttt>
<CR> entered at end
of string.
Tare Weight: Six digits, right justified,
dummy zeros, decimal point with no
leading zeroes except for immediately
preceding the decimal point.
Leading zeroes transmitted as spaces.
Status Word C: ASCII 20h (space)
7
6
Parity
0
Even parity bit:
Requires EDP Port setup.
0 = Gross Display Mode
1 = Net Display Mode
<UNIT>
<TERM>
<CR><LF>
or
<CR>
<CR>
5
4
3
2
1
1
0
0
0
0
0
0
Need help?
Do you have a question about the Revolution 680 Synergy Plus and is the answer not in the manual?
Questions and answers