SPECIFICATIONS

8.1
Rating
200 V class
Model FR-F820-[ ]
SLD
Applicable motor
capacity (kW)

LD
SLD
Rated capacity
(kVA)

LD
SLD
Rated current
(A)
LD
Overload
SLD
current rating
LD

Rated voltage

Rated input
AC voltage/frequency
Permissible AC voltage fluctuation
Permissible frequency fluctuation
SLD
Rated input
current (A)

LD
Power supply
SLD
capacity (kVA)
LD

Protective structure (IEC 60529)

Cooling system
Approx. mass (kg)

The applicable motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi 4-pole standard motor.

The rated output capacity indicated assumes that the output voltage is 220 V for 200 V class.

The % value of the overload current rating indicated is the ratio of the overload current to the inverter's rated output current. For repeated duty, allow time for the inverter
and motor to return to or below the temperatures under 100% load.

The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed within the setting range. However, the maximum
point of the voltage waveform at the inverter output side is the power supply voltage multiplied by about

The rated input current indicates a value at a rated output voltage. The impedance at the power supply side (including those of the input reactor and cables) affects the
rated input current.

The power supply capacity is the value when at the rated output current. It varies by the impedance at the power supply side (including those of the input reactor and
cables).

FR-DU08: IP40 (except for the PU connector section)
00046 00077 00105 00167 00250 00340 00490 00630 00770 00930 01250 01540 01870 02330 03160 03800 04750
0.75K
1.5K
2.2K
3.7K
5.5K
0.75
1.5
2.2
3.7
5.5
7.5
0.75
1.5
2.2
3.7
5.5
7.5
1.8
2.9
4
6.4
10
13
1.6
2.7
3.7
5.8
8.8
12
4.6
7.7
10.5
16.7
25
34
4.2
7
9.6
15.2
23
31
110% 60 s, 120% 3 s (inverse-time characteristics) at surrounding air temperature 40°C
120% 60 s, 150% 3 s (inverse-time characteristics) at surrounding air temperature 50°C
Three-phase 200 to 240 V
Three-phase 200 to 240 V 50 Hz/60 Hz
170 to 264 V 50 Hz/60 Hz
±5%
5.3
8.9
13.2
19.7
31.3
45.1
5
8.3
12.2
18.3
28.5
41.6
2
3.4
5
7.5
12
17
1.9
3.2
4.7
7
11
16
Enclose type (IP20)
Self-cooling
Forced air cooling
1.9
2.1
3.0
3.0
3.0
6.3
7.5K
11K
15K
18.5K
22K
30K
11
15
18.5
22
30
11
15
18.5
22
30
19
24
29
35
48
17
22
27
32
43
49
63
77
93
125
45
58
70.5
85
114
62.8
80.6
96.7
115
151
58.2
74.8
90.9
106
139
24
31
37
44
58
22
29
35
41
53
Open type (IP00)
6.3
8.3
15
15
15
.
Rating
37K
45K
55K
75K
90K
37
45
55
75
90/110 132
37
45
55
75
90
110
59
71
89
120
145
181
53
65
81
110
132
165
154
187
233
316
380
475
140
170
212
288
346
432
185
221
269
316
380
475
178
207
255
288
346
432
70
84
103
120
145
181
68
79
97
110
132
165
22
42
42
54
74
74
SPECIFICATIONS