Setting
Pr.
Name
range
0 to 500A, 9999

Torque current/Rated
859
PM motor current
0 to 3600A,
9999

0 to 500A, 9999
Second motor torque

860
current/Rated PM
0 to 3600A,
motor current
9999

864
Torque detection
0 to 400%
Torque monitoring
866
0 to 400%
reference
867
AM output filter
0 to 5s
Terminal 1 function
868
0, 4, 9999
assignment
869
Current output filter
0 to 5s

Speed detection
870
0 to 5Hz
hysteresis
Input phase loss
872
0, 1
protection selection
874
OLT level setting
0 to 400%
Regeneration
882
avoidance operation
0 to 2
selection
Regeneration
883
avoidance operation
300 to 800V
level
Regeneration avoidance
884
at deceleration detection
0 to 5
sensitivity
Regeneration avoidance
885
compensation frequency
0 to 590Hz, 9999 6Hz
limit value
Regeneration
886
avoidance voltage gain 0 to 200%
888
Free parameter 1
0 to 9999
889
Free parameter 2
0 to 9999
Cumulative power
891
0 to 4, 9999
monitor digit shifted times
892
Load factor
30 to 150%
Energy saving monitor
0.1 to 55kW
893
reference (motor
0 to 3600kW
capacity)
Control selection during
894
commercial power-
0 to 3
supply operation
Power saving rate
895
0, 1, 9999
reference value
896
Power unit cost
0 to 500, 9999
Power saving monitor
0, 1 to 1000h,
897
average time
9999
Power saving cumulative
898
0, 1, 10, 9999
monitor clear
Operation time rate
899
0 to 100%, 9999 9999
(estimated value)
C0
FM/CA terminal
(900)
calibration


C1
AM terminal calibration ―
(901)

C2
Terminal 2 frequency
0 to 590Hz
(902)
setting bias frequency

C3
Terminal 2 frequency
0 to 300%
(902)
setting bias

125
Terminal 2 frequency
0 to 590Hz
(903)
setting gain frequency

C4
Terminal 2 frequency
0 to 300%
(903)
setting gain

C5
Terminal 4 frequency
0 to 590Hz
(904)
setting bias frequency

C6
Terminal 4 frequency
0 to 300%
(904)
setting bias

126
Terminal 4 frequency
0 to 590Hz
(905)
setting gain frequency

C7
Terminal 4 frequency
0 to 300%
(905)
setting gain

C12
Terminal 1 bias
0 to 590Hz
(917)
frequency (speed)

C13
Terminal 1 bias (speed) 0 to 300%
(917)

C14
Terminal 1 gain
0 to 590Hz
(918)
frequency (speed)

C15
Terminal 1 gain (speed) 0 to 300%
(918)

C16
Terminal 1 bias
0 to 400%
(919)
command (torque)

C17
Terminal 1 bias (torque) 0 to 300%
(919)

C18
Terminal 1 gain
0 to 400%
(920)
command (torque)

C19
Terminal 1 gain (torque) 0 to 300%
(920)

C8
Current output bias
0 to 100%
(930)
signal

C9
Current output bias
0 to 100%
(930)
current

Initial
Pr.
Name
value
C10
Current output gain
(931)
signal
9999

C11
Current output gain
(931)
current

C38
Terminal 4 bias
9999
(932)
command (torque)

C39
Terminal 4 bias (torque) 0 to 300%
150%
(932)

C40
Terminal 4 gain
150%
(933)
command (torque)

0.01s
C41
Terminal 4 gain (torque) 0 to 300%
(933)

0
C42
PID display bias
(934)
coefficient

0.02s
C43
PID display bias analog
(934)
value

0Hz
C44
PID display gain
(935)
coefficient

0
C45
PID display gain analog
(935)
value

120/110%

Input voltage mode
977
selection
0
Parameter copy alarm
989
release
DC380/
DC760V

990
PU buzzer control
991
PU contrast adjustment 0 to 63
0
Operation panel setting
992
dial push monitor
selection
100%
997
Fault initiation
9999
PM parameter
9999
998
initialization
9999
Automatic parameter
999
setting
100%
1000
Parameter for manufacturer setting. Do not set.
LD/SLD

rated inverter
Lq tuning target current
1002

current

adjustment coefficient
1006
Clock (year)
0
9999
9999
1007
Clock (month, day)
9999
9999
0Hz
0%
60/50Hz

1008
Clock (hour, minute)
100%
0Hz
20%
60/50Hz

100%
Emergency drive
1013
running speed after
0Hz
retry reset
Integral stop selection
1015
0%
at limited frequency
PTC thermistor
60/50Hz
1016
protection detection

time
100%
1020
Trace operation selection 0 to 4
1021
Trace mode selection
0%
1022
Sampling cycle
Number of analog
1023
0%
channels
1024
Sampling auto start
150%
1025
Trigger mode selection 0 to 4
Number of sampling
100%
1026
before trigger
0%
0%
Setting
Initial
Pr.
range
value
Analog source selection
1027
0 to 100%
100%
(1ch)
Analog source selection
1028
(2ch)
0 to 100%
100%
Analog source selection
1029
(3ch)
0 to 400%
0%
Analog source selection
1030
(4ch)
20%
Analog source selection
1031
(5ch)
0 to 400%
150%
Analog source selection
1032
(6ch)
100%
Analog source selection
1033
(7ch)
0 to 500.00,
9999
Analog source selection
9999
1034
(8ch)
0 to 300%
20%
1035
Analog trigger channel
Analog trigger operation
0 to 500.00,
1036
9999
selection
9999
1037
Analog trigger level
0 to 300%
100%
Digital source selection
1038
(1ch)
0, 1
0
Digital source selection
1039
(2ch)
10
10


Digital source selection
100
100


1040
(3ch)
0, 1
1
Digital source selection
58
1041
(4ch)
0 to 3, 5 to 14,
Digital source selection
1042
17, 18, 20,
(5ch)
23 to 25, 34, 38,
Digital source selection
40 to 45,
0
1043
(6ch)
50 to 57, 61, 62,
64, 67, 68,
Digital source selection
1044
81 to 96, 98,100
(7ch)
0 to 255, 9999
9999
Digital source selection
1045
(8ch)
0, 12, 112,
8009, 8109,
0
1046
Digital trigger channel
9009, 9109
Digital trigger operation
1047
1, 2,10 to 13,
selection
9999
20, 21, 9999
1048
Display-off waiting time
1049
USB host reset
50 to 150%,
9999
1106
Torque monitor filter
9999
1107
Running speed monitor filter 0 to 5s, 9999
2000 to 2099
2000
Excitation current
101 to 131,
1108
monitor filter
201 to 229,
301 to 331,
Pre-charge change
1132
401 to 430,
increment amount
501 to 531,
Second pre-charge
601 to 630,
101
1133
change increment
701 to 731,
amount
801 to 831,
901 to 930,
1134
Parameter for manufacturer setting. Do not set.
1001 to 1031,
1135
1101 to 1130,
Second PID display
1201 to 1231
1136
bias coefficient
0 to 59, 100 to
Second PID display
159, 200 to 259,
1137
bias analog value
300 to 359,
400 to 459,
Second PID display gain
1138
500 to 559,
coefficient
600 to 659,
Second PID display
700 to 759,
1139
gain analog value
800 to 859,
900 to 959,
Second PID set point/
1000 to 1059,
1140
deviation input
1100 to 1159,
selection
1200 to 1259,
0
Second PID measured
1300 to 1359,
1141
value input selection
1400 to 1459,
1500 to 1559,
Second PID unit
1142
1600 to 1659,
selection
1700 to 1759,
1143
Second PID upper limit 0 to 100%, 9999 9999
1800 to 1859,
1144
Second PID lower limit 0 to 100%, 9999 9999
1900 to 1959,
2000 to 2059,
Second PID deviation
1145
2100 to 2159,
limit
2200 to 2259,
Second PID signal
2300 to 2359
1146
operation selection
Second output
0 to 590Hz
60/50Hz

1147
interruption detection
time
0, 1, 10, 11
0
Second output
1148
interruption detection
level
0 to 60s
0s
Second output
1149
interruption cancel level 900 to 1100%
0
1150
0 to 2
0
to
User parameters 1 to 50 0 to 65535
1199
0 to 9
2
PID gain tuning timeout
1211
1 to 8
4
time
Step manipulated
0, 1
0
1212
amount
0
Step responding
1213
0 to 100%
90%
sampling cycle
Timeout time after the
1214
maximum slope
Limit cycle output upper
1215
limit
Limit cycle output lower
1216
limit
Parameter list
Setting
Initial
Name
range
value
201
202
1 to 3, 5 to 14,
203
17, 18, 20, 23,
24, 34, 40 to 42,
204
52 to 54, 61, 62,
64, 67, 68,
81 to 96, 98,
205
201 to 213,
230 to 232, 237,
206
238
207
208
1 to 8
1
0, 1
0
600 to 1400
1000
1
2
3
4
1 to 255
5
6
7
8
1 to 8
1
0, 1
0
0 to 60min
0min
0, 1
0
0 to 5s, 9999
9999
9999
0 to 5s, 9999
9999
0 to 100%, 9999 9999
0 to 100%, 9999 9999
0 to 500, 9999
9999
0 to 300%
20%
0 to 500, 9999
9999
0 to 300%
100%
1 to 5
2
1 to 5, 101 to 105 3
0 to 43, 9999
9999
0.0 to 100.0%,
9999
9999
0 to 3, 10 to 13 0
0 to 3600s, 9999 1s
0 to 590Hz
0Hz
1000%
0
1 to 9999s
100s
900 to 1100%
1000%
0.01 to 600s
1s
1 to 9999s
10s
900 to 1100%
1100%
900 to 1100%
1000%
21