T R O U B L E S H O O T I N G T I P S
Unit does not turn on:
• Confirm the unit has AC power.
• Check if circuit breaker that controls the AC outlet the light is plugged into is not tripped.
• Confirm the AC power cord from the light is not damaged or cut.
• Check the fuse and see if it needs to be replaced.
• If none of these solutions work, please contact ADJ Customer Service.
Unit does not respond to DMX:
Check that the DMX cables are connected properly and are wired correctly (pin 3 is "hot"; on
some other DMX devices pin 2 may be 'hot'). Also, check that all cables are connected to the
right connectors; it does matter which way the inputs and outputs are connected.
No light output in Dimmer Mode:
Be sure that the strobe setting is set to value 255.
Unit does not respond to the remote control:
If remote is not responding to button presses, please check battery and replace if needed.
Ensure that RFActive mode has been turned on and is active.
F R E Q U E N T L Y A S K E D Q U E S T I O N S
Listed below are a few answers to common questions users may have.
Can the fuse be replaced?
Yes, for replacement instructions, please see page 24 for instructions.
What degree is the light beam?
Each pinspot has an ACL lens that produces a 5-degree beam. The beam angles can be adjusted using
the included 10-degree or 45-degree frost filters.
What size is the battery for the RF Remote Control?
The battery is a 23A 12V battery and can be purchased from
parts.adj.com