With this feature you can link the fixtures to one another using the power cable input and output
sockets.
The maximum number of units that can be linked in this manner is as follows:
• 6 units with 120V power.
• 15 units with 240V power.
NOTE: USE CAUTION WHEN POWER LINKING OTHER FIXTURES AS THE POWER
CONSUMPTION OF OTHER MODEL FIXTURES MAY EXCEED THE MAX POWER OUTPUT ON
THIS FIXTURE! CHECK SILK SCREEN FOR MAX AMPS.
Below is a common problem that the user may encounter, with a potential solution.
Unit not responding to DMX:
Check that the DMX cables are connected and wired properly (pin 3 is "hot"; on some other DMX
devices pin 2 may be "hot"). Also, check that all cables are connected to the proper connectors, as
the manner in which the input and outputs are connected does have an effect on how the devices
operate.
Due to fog residue, smoke, and dust, cleaning the internal and external optical lenses must be car-
ried out periodically to optimize light output.
• Use normal glass cleaner and a soft cloth to wipe down the outside casing.
• Periodically clean the external optics with glass cleaner and a soft cloth.
• Always be sure to dry all parts completely before plugging the unit back in.
Cleaning frequency depends on the environment in which the fixture operates (i.e. smoke, fog resi-
due, dust, dew).