Advertisement

Quick Links

HYDRO SPOT 2
User Manual

Advertisement

Table of Contents
loading

Summary of Contents for ADJ HYD320

  • Page 1 HYDRO SPOT 2 User Manual...
  • Page 2 ©2022 ADJ Products, LLC all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. ADJ Products, LLC logo and identifying product names and numbers herein are trademarks of ADJ Products, LLC. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted.
  • Page 3: Table Of Contents

    C O N T E N T S Introduction Limited Warranty (USA Only) Warranty Registration | Features Safety Precautions Overview Installation Remote Device Management (RDM) Color Wheel Animation Wheel Gobos Control Panel System Menu DMX Set Up DMX Traits White Color Temperature Presets Dim Speeds Dim Modes Primary-Secondary Set Up | Multi Unit Power Linking...
  • Page 4: Introduction

    BOX CONTENTS Omega Brackets 1.83M locking power cable CUSTOMER SUPPORT Contact ADJ Service for any product related service and support needs. Also visit forums.adj.com with questions, comments or suggestions. ADJ SERVICE USA - Monday - Friday 8:00am to 4:30pm PST 323-582-2650 | Fax: 323-832-2941 | support@adj.com...
  • Page 5: Limited Warranty (Usa Only)

    All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, ADJ Products, LLC will pay return shipping charges only to a designated point within the United States. If the entire instrument is sent, it must be shipped in its original package. No accessories should be shipped with the product.
  • Page 6: Warranty Registration | Features

    WA R R A N T Y R E G I S T R AT I O N Please fill out the enclosed warranty card to validate your purchase. All returned service items, whether under warranty or not, must be freight pre-paid and accompanied by a return authorization (R.A.) number.
  • Page 7: Safety Precautions

    S A F E T Y P R E C A U T I O N S PROTECTION CLASS 1 - FIXTURE MUST BE PROPERLY GROUNDED. THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY REPAIRS YOURSELF, AS DOING SO WILL VOID YOUR MANUFACTURER’S WARRANTY.
  • Page 8: Overview

    O V E R V I E W Tilt Lock Lock Mode Button Button Power Display Power Left Down Fuse Enter Right Screen Button Button Button Button Carry Carry Handle Handle Safety Omega Cable Bracket Loop Mounting Points...
  • Page 9: Installation

    I N S TA L L AT I O N DO NOT INSTALL THE FIXTURE IF YOU ARE NOT QUALIFIED TO DO SO! Fixture MUST be installed following all local, national, and country commercial electrical and construc- tion codes and regulations. When installing the unit, the trussing or area of installation must be able to support at least 10 times the weight of the unit and any attached accessories without any deformation.
  • Page 10 I N S TA L L AT I O N CLAMP MOUNTING This fixture features mounting points on the underside for the attachment of two Omega brackets. Additionally, the unit also features a safety cable loop on the underside, near one of the carry handles (see the illustration below).
  • Page 11 LEDs. This issue is not specific only to ADJ lighting fixtures, but rather it is a common issue with lighting fixtures from all manufacturers. Although there is no true way to fully prevent this issue from happening, the guidelines below can reduce the risk of potential damage.
  • Page 12: Remote Device Management (Rdm)

    R E M O T E D E V I C E M A N A G E M E N T ( R D M ) NOTE: In order for RDM to work properly, RDM enabled equipment must be used throughout the entire system, including DMX data splitters and wireless systems.
  • Page 13: Color Wheel

    C O L O R W H E E L S Blue Green Amber Orange CTB 5600° High CRI...
  • Page 14: Animation Wheel

    A N I M AT I O N W H E E L...
  • Page 15: Gobos

    G O B O S DESIGNS GOBO WHEEL 1 - ROTATING GOBOS GOBO WHEEL 2 - FIXED GOBOS GOBO DIMENSIONS Gobo Type Thickness Inner (Viewable) Diameter Outer Diameter Rotating 0.02in (0.5mm) 0.75in (19.0mm) 0.91in (23.0mm) Fixed 0.03in (0.8mm) 0.75in (19.0mm)
  • Page 16 G O B O S ROTATING GOBO HOLDER DIMENSIONS Orientation Point 0.23in 0.07in (5.9mm) (1.8mm) 0.02in (0.5mm) 1.83in (46.6mm)
  • Page 17 GOBOS REPLACEMENT PROCEDURE 1. Place the device on a flat, stable surface, and allow the device to cool down for at least 1 hour before beginning this procedure. 2. Engage both the pan and tilt locks, and remove the head covers. 3.
  • Page 18: Control Panel

    C O N T R O L PA N E L The Hydro Spot 2 features a display screen with a 6-button control pad, which can be used to easily adjust any device settings. • The MODE button cycles through main menu options, or returns to the previous menu without mak- ing changes.
  • Page 19: System Menu

    S Y S T E M M E N U DMX Address 001 - xxx Basic 24 DMX Channel Standard 29 Mode Extended 36 Holds last settings Hold Last when DMX signal is lost Takes all channels DMX SETTINGS Blackout to 0 when DMX signal is lost No DMX Status...
  • Page 20 S Y S T E M M E N U Standard Stage Dim Modes Architectural Theatre Stage 2 Dim Speed 0.1s - 10.0s 900 Hz-1500 Hz, 2500 Hz, 4000 Hz, 5000 Hz, 6000 Hz, 10 Default = 1200 Hz LED Refresh Rate KHz, 15 KHz, 20 KHz, 25 KHz Square Linear...
  • Page 21 S Y S T E M M E N U 000 - 255 Pan Fine 000 - 255 MANUAL Tilt 000 - 255 CONTROL Tilt Fine 000 - 255 Speed 000 - 255 Program 1 Fade 000 - 255 Speed 000 - 255 Program 2 INTERNAL...
  • Page 22 S Y S T E M M E N U DMX Values Pan Fine INFORMATION List errors one by xxxxx Error Logs Yes / No Reset Error Log Passcode = 050 Software Version U:xxx...
  • Page 23: Dmx Set Up

    2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line. Using a cable terminator (ADJ part number Z-DMX/T) will reduce the risk of erratic behavior.
  • Page 24 D M X S E T U P DMX ADDRESSING. All fixtures should be given a DMX starting address when using a DMX controller, so the correct fixture responds to the correct control signal. This digital starting address is the channel number from which the fixture starts to “listen”...
  • Page 25: Dmx Traits

    D M X T R A I T S CHANNEL FUNCTION VALUES 24 CH 29 CH 36 CH 000 - 255 Pan Movement, 540/630 000 - 255 Pan Fine 000 - 255 Tilt Movement, 270 000 - 255 Tilt Fine 000 - 255 Cyan, 0% to 100% 000 - 255 Cyan Fine 000 - 255 Magenta, 0% to 100%...
  • Page 26 D M X T R A I T S CHANNEL FUNCTION VALUES 24 CH 29 CH 36 CH Color Macros 000 - 031 Off 032 - 039 Macro 1 040 - 047 Macro 2 048 - 055 Macro 3 056 - 063 Macro 4 064 - 071 Macro 5 072 - 079 Macro 6 080 - 087 Macro 7...
  • Page 27 D M X T R A I T S CHANNEL FUNCTION VALUES 24 CH 29 CH 36 CH Gobo Wheel 1 (continued) 080 - 094 Gobo 1 Shake, slow to fast 095 - 109 Gobo 2 Shake, slow to fast 110 - 124 Gobo 3 Shake, slow to fast 125 - 139 Gobo 4 Shake, slow to fast 140 - 154 Gobo 5 Shake, slow to fast...
  • Page 28 D M X T R A I T S CHANNEL FUNCTION VALUES 24 CH 29 CH 36 CH Shutter 000 - 031 Shutter Closed 032 - 063 Shutter Open 064 - 095 Strobe, slow to fast 096 - 127 Shutter Open 128 - 159 Pulse Effect, slow to fast 160 - 191 Shutter Open 192 - 223 Random Strobe, slow to fast...
  • Page 29 D M X T R A I T S CHANNEL FUNCTION VALUES 24 CH 29 CH 36 CH 000 - 255 Zoom, narrow to wide 000 - 255 Zoom Fine 000 - 255 Medium Frost, 0% to 100% 000 - 255 Heavy Frost, 0% to 100% Animation 000 - 005 Wheel Rotation Off 006 - 128 Animation Index, 0°...
  • Page 30 D M X T R A I T S CHANNEL FUNCTION VALUES 24 CH 29 CH 36 CH Special Functions (continued) 080 - 084 Color Reset (hold 3s) 085 - 089 Gobo Reset (hold 3s) 090 - 094 Focus and Zoom Reset (hold 3s) 095 - 099 Shutter Reset (hold 3s) 100 - 104 No Function 105 - 109 Other Motors Reset (hold 3s)
  • Page 31 D M X T R A I T S CHANNEL FUNCTION VALUES 24 CH 29 CH 36 CH Refresh Rates (Hz, continued) 1060 1070 1080 1090 1100 1110 1120 1130 1140 1150 1160 1170 1180 1190 1210 1220 1230 1240 1250 1260 1270...
  • Page 32 D M X T R A I T S CHANNEL FUNCTION VALUES 24 CH 29 CH 36 CH Refresh Rates (Hz, continued) 1450 1460 1470 1480 1490 1500 2500 4000 5000 6000 10,000 15,000 20,000 25,000 Internal Program 1 (scenes 1-8, hold 3s) Internal Program 2 (scenes 9-16, hold 3s) Internal Program 3 (scenes 17-24, hold 3s) Internal Program 4 (scenes 25-32, hold 3s)
  • Page 33: White Color Temperature Presets

    W H I T E C O L O R T E M P E R AT U R E P R E S E T S COLOR COLOR VALUES TEMPERATURE (K) VALUES TEMPERATURE (K) 2700 4700 2800 4800 2900 4900 3000 5000...
  • Page 34: Dim Speeds

    D I M S P E E D S DMX VALUES DELAY TIME 0.1 sec 0.2 sec 0.3 sec 0.4 sec 0.5 sec 0.6 sec 0.7 sec 0.8 sec 0.9 sec 1.0 sec 1.5 sec 2.0 sec 3.0 sec 4.0 sec 5.0 sec 6.0 sec 7.0 sec...
  • Page 35: Dim Modes

    D I M M O D E S...
  • Page 36: Primary-Secondary Set Up | Multi Unit Power Linking

    P R I M A R Y- S E C O N D A R Y S E T U P This function allows you to link units together to run in a Primary-Secondary set-up, in which one unit will act as the controlling unit and the others will react to the controlling unit’s built-in programs. Any unit can be configured to act as a Primary or as a Secondary, but only one unit in a given system can be programmed to act as the Primary.
  • Page 37: Maintenance Guidelines

    Regular inspections are recommended to ensure proper function and extended life. There are no user serviceable parts inside this fixture. Please refer all other service issues to an authorized ADJ service technician. Should you need any spare parts, please order genuine parts from your local ADJ dealer.
  • Page 38: Torque Settings For Screws

    T O R Q U E S E T T I N G S F O R S C R E W S ALL SCREWS MUST BE TIGHTENED WITH A TORQUE DRIVER. All screws are Allen head screws. Please refer to the table and diagram below for screw locations, quantity, and torque settings. Zone Description Quantity...
  • Page 39 CAUTION! DO NOT OVER TORQUE SCREWS AS THIS CAN CAUSE LEAKAGE ISSUES! TO CONFIRM THE IP65 INTEGRITY AFTER A LAMP REPLACEMENT, TEST THE FIXTURE USING THE IP TESTER. CONTACT ADJ SERVICE FOR MORE DETAILS. CAUTION! THE USE OF PROTECTIVE GLOVES AND SAFETY GOGGLES IS STRONGLY RECOMMENDED WHILE PERFORMING THE IP PRESSURE TEST! AVOID PLACING YOUR FACE, EYES, HANDS, ETC IN CLOSE PROXIMITY TO THE FIXTURE’S LENS...
  • Page 40: Error Codes

    E R R O R C O D E S When power is applied, the unit will automatically enter a “Reset/Test” mode. This mode brings all the internal motors to a home position. If there is an internal problem with one or more of the motors, an error code will flash in the display, as described in the chart below.
  • Page 41: Dimensional Drawings

    D I M E N S I O N A L D R AW I N G S Drawings not to scale...
  • Page 42: Specifications

    S P E C I F I C AT I O N S Light Source: • Color LCD display with 6-button function menu • 320W Cool White LED Engine (50,000 hr.) • Control Mode: DMX512 or internal programs • 15,000 Lumens •...

This manual is also suitable for:

Hydro spot 2

Table of Contents