Lubrication Guide- 24Kt Compressors; Application Guide; Lubrication Change Recommendations And Maintenance - Sullair TS-32S Operator's Manual And Parts List

Industrial rotary screw air compressor 400-600hp/298-447kw air-cooled & water-cooled standard and 24kt
Table of Contents

Advertisement

Section 3
SPECIFICATIONS
Figure 3-1 Fluid Fill Location

3.3 LUBRICATION GUIDE- 24KT COMPRESSORS

See Figure 3-1. Sullair 24KT compressors are filled
with a lubricant which rarely ever needs to be
changed. In the event a change of fluid or make-up
fluid is required, use only Sullair 24KT fluid.
Mixing of other lubricants within the compressor
unit will void all warranties.
20
Sullair recommends that 24KT sample be taken at
the first filter change and sent to the factory for
analysis. This is a free service. A sample kit with
instructions and self addressed container is to be
supplied by your Sullair representative at start-up.
The user will receive an analysis report with recom-
mendations.
A 24KT sample should be sent in annually, after
the first year.

3.4 APPLICATION GUIDE

Sullair encourages the user to participate in a fluid
analysis program with the fluid suppliers. This could
result in a fluid change interval differing from that
stated in the manual. Contact your Sullair dealer for
details.
3.5 LUBRICATION CHANGE RECOMMENDATIONS
AND MAINTENANCE
LUBRICANT
FLUID
CHANGE
Sullube
A, D
24KT
E, D
A - 8,000 Hours or once a year
B - When measured pressure loss exceeds 20 psig (1.3 bar).
C - When measured pressure loss exceeds 10 psig (0.7 bar).
D - When required by fluid analysis or known contamination.
E - Does not require replacement during normal service condi-
tions.
F- Every 1000 hours.
FLUID FILTER
SEPARATOR
CHANGE
CHANGE
F, B
A, C
F, B
A, C