Sullair Series Ts-32S Specifications; Lubrication Guide- Standard Compressors - Sullair TS-32S Operator's Manual And Parts List

Industrial rotary screw air compressor 400-600hp/298-447kw air-cooled & water-cooled standard and 24kt
Table of Contents

Advertisement

3.1 SULLAIR SERIES TS-32S SPECIFICATIONS

60 Hz MODEL
(AC)
(WC)
50Hz MODEL
(AC)
(WC)
(I) Add 1 in./2.5 cm for enclosure. Add 37 in./94 cm (200-350hp/149-261kw) for servicing the separator.
(II) Add 1,040 lbs./ 472 kg for air-cooled enclosure package.
(III) Add 1,800 lbs./ 816 kg for water-cooled enclosure package.
For noise level information, please contact the Sullair Factory Service Department.
COMPRESSOR:
Type:
Standard Operating Pressure:
Bearing Type:
Ambient Temperature (Max.):
Lubricant:
Coolant:
Fluid Capacity:
Control Type:
Options:
MOTOR:
Size:
Type:
Options:
Speed:
Starter:
3.2 LUBRICATION GUIDE- STANDARD COMPRES-
SORS
Refer to Figure 3-1. Sullair TS-32S Series standard
compressors are filled with Sullube fluid as factory
fill.
Mixing of other lubricants within the compres-
sor unit will void all warranties.
Sullube fluid should be changed every 8000 hours
LENGTH
(IN)
175
175
LENGTH
(CM)
444.5
444.5
WIDTH
(IN)
84
84
WIDTH
(CM)
213
213
Positive displacement, fluid-lubricated, twin rotary screws
400, 500 and 600hp/ 298, 373 and 447kw
Anti-friction
104ºF/40ºC; consult factory for higher ambient temperatures
See Sections 3.2 and
3.3
Pressurized Sullube
48 gallons/ 181.7 liters
Electro-pneumatic
Cold Weather Package, EES Remote Heat Recovery,
Enclosure, Phase Monitor Relay, Remote Cooler Pack- Air-
cooled, Water Solenoid Valve, Water Regulator Valve
400-600hp/ 298-447kw- Consult factory for specific voltages
Open Dripproof enclosure, 3-phase, 60 Cycles
104ºF / 40ºC Maximum Ambient Temperature
Various voltages, TEFC enclosure: CE approved, Motor-OPD
Premium Efficient, Motor- ODP Standard Efficient -3300V
1780 RPM (60Hz), 1475 RPM (50Hz)
Full-voltage, Wye-delta, or Solid State; various voltages
or once a year, whichever comes first. The fluid
should be changed more frequently under severe
operating conditions, such as high ambient temper-
atures coupled with high humidity, or when high
particulate level, corrosive gases or strong oxidizing
gases are present in the air.
Maintenance of all other components is still recom-
mended as indicated in the Maintenance section of
this manual.
SPECIFICATIONS
HEIGHT (I)
WEIGHT
(IN)
(LB)
93
93
HEIGHT (I)
WEIGHT
(CM)
(KG)
218
(III)
218
(III)
on Lubricant
Section 3
(II)
(II)
19

Hide quick links:

Advertisement

Table of Contents
loading