Lubrication Guide- 24Kt Compressors; Lubrication Guide- Optional Fluid - Sullair LS-200S Operator's Manual And Parts List

Industrial air compressor
Table of Contents

Advertisement

Section 3
SPECIFICATIONS
Figure 3-1 Fluid Fill Port
Maintenance of all other components is still recom-
mended as indicated in the Operator's Manual.
Sullair encourages the user to participate in a fluid
analysis program with the fluid suppliers. This could
result in a fluid change interval differing from that
stated in the manual. Contact your Sullair dealer for
details.

3.3 LUBRICATION GUIDE- 24KT COMPRESSORS

Before changing or recharging system fluid
always relieve all pressure from the sump tank
and all compressor lines.
DO NOT mix different types of fluids.
MIXING OF OTHER LUBRICANTS WITHIN THE
COMPRESSOR UNIT WILL VOID ALL WAR-
RANTIES.
Flush system when switching lubricant brands.
Refer to Figure 3-1. Sullair 24KT compressors are
filled with a lubricant which rarely needs to be
changed. In the event a change of fluid is required,
20
When performing a fluid
change or topping off the
fill, the proper level should
be at half of the sight glass,
with the machine off.
use only Sullair 24KT fluid.
Sullair recommends that a 24KT sample be taken at
the first filter change and sent to the factory for
analysis. This is a free service. A sample kit with
instructions and self-addressed container is to be
supplied by your Sullair Representative at start-up.
The user will receive an analysis report with recom-
mendations.

3.4 LUBRICATION GUIDE- OPTIONAL FLUID

Before changing or recharging system fluid
always relieve all pressure from the sump tank
and all compressor lines.
DO NOT mix different types of fluids.
MIXING OF OTHER LUBRICANTS WITHIN THE
COMPRESSOR UNIT WILL VOID ALL WAR-
RANTIES.
Flush system when switching lubricant brands.
Refer to Figure 3-1. Sullair compressors may use
SRF 1/4000 fluid as an optional factory fill.
SRF 1/4000 fluid should be changed every 4000
hours or once a year, whichever comes first. The
fluid should be changed more frequently under
severe operating conditions, such as high ambient
temperatures coupled with high humidity, or when
high particulate level, corrosive gases or strong oxi-
dizing gases are present in the air.
For extended life synthetic lubricants contact the
nearest Sullair representative.
Maintenance of all other components is still recom-
mended as indicated in the Operator's Manual.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

V-200sVcc-200s