MOTOR: (60 Cycle Compressors)
STANDARD MODELS
Size
200HP/150KW --- 350HP/261KW, 460V
Type
Open Dripproof, Three Phase, 60 Cycles
40_C Maximum Ambient Temperature,
Options Available: Other Voltages
TEFC also Available
Speed
1770 RPM
MOTOR: (50 Cycle Compressors)
STANDARD MODELS
Size
200HP/150KW --- 350HP/261KW, 380V
Type
Open Dripproof, Three Phase, 50 Cycles
40_C Maximum Ambient Temperature
Options Available: Other Voltages
TEFC also Available
Speed
1500 RPM
LUBRICATION GUIDE---STANDARD COMPRES-
SORS
Sullair standard compressors are filled with Sul-
lube 32 fluid as factory fill. MIXING OF OTHER
FLUIDS WITHIN THE COMPRESSOR WILL VOID
ALL WARRANTIES.
WA R N I N G
!
To be sure that you receive the correct fluid for
your compressor, when ordering fluid, always
confirm your compressor's fluid fill with the parts
technician by using your compressor's serial
number.
Sullube 32 fluid should be changed every 8000
hours or once a year, whichever comes first. The
fluid should be changed more frequently under se-
vere operating conditions, such as high ambient
temperatures coupled with high humidity, or when
high particulate level, corrosive gases or strong oxi-
dizing gases are present in the air.
Sullair compressors may use SRF 1/4000 fluid as
an optional factory fill.
WA R N I N G
!
Mixing of other fluids within the compressor will
void all warranties.
SRF 1/4000 fluid should be changed every 4000
hours or once a year, whichever comes first. The
fluid should be changed more frequently under se-
vere operating conditions, such as high ambient
temperatures coupled with high humidity, or when
high particulate level, corrosive gases or strong oxi-
dizing gases are present in the air.
Section 3
SPECIFICATIONS
24KT MODELS
200HP/150KW --- 350HP/261KW, 460V
Open Dripproof, Three Phase, 60 Cycles
40_C Maximum Ambient Temperature,
Options Available: Other Voltages
TEFC also Available
1770 RPM
24KT MODELS
200HP/150KW --- 350HP/261KW, 380V
Open Dripproof, Three Phase, 50 Cycles
40_C Maximum Ambient Temperature,
Options Available: Other Voltages
TEFC also Available
1500 RPM
WA R N I N G
!
"The Plastic Pipe Institute recommends against the
use of thermoplastic pipe to transport compressed
air or other compressed gases in exposed above
ground locations, e.g. in exposed plant piping." (I)
Sullube 32 should not be used with PVC piping sys-
tems. It may affect the bond at cemented joints. Cer-
tain other plastic materials may also be affected.
(I) Plastic Pipe Institute, Recommendation B,
Adopted January 19, 1972.
For other extended life synthetic lubricants contact
the nearest Sullair representative.
Maintenance of all other components is still recom-
mended as indicated in the Maintenance section of
this manual.
LUBRICATION GUIDE--- 24KT COMPRESSORS
Sullair 24KT compressors are filled with a lubricant
which rarely needs to be changed. In the event a
change of fluid or make---up fluid is required, use
only Sullair 24KT fluid. MIXING OF OTHER FLU-
IDS WITHIN THE COMPRESSOR WILL VOID
ALL WARRANTIES.
Sullair recommends that a 24KT sample be taken
at the first filter change and sent to the factory for
analysis. This is a free service. A sample kit with in-
structions and self---addressed container will be
supplied by your Sullair representative at start---up.
Upon completion of the sample analysis, the user
will receive a report with recommendations.
APPLICATION GUIDE
Sullair encourages the user to participate in a fluid
analysis program with the fluid suppliers. This
could result in a fluid change interval differing from
that stated in the manual. Contact your Sullair
dealer for details.