ruckusSCGPmipLMAFailOverTrap
Table 239. ruckusSCGPmipLMAFailOverTrap
Object Name
Parent Node
Object Identifier
Trap Severity
Bindings
Description
Generated by Event
Code
ruckusSCGPmipBindingFailureTrap
Table 240. ruckusSCGPmipBindingFailureTrap
Object Name
Parent Node
Object Identifier
Trap Severity
Bindings
Description
SCG-200 and vSZ-H SNMP Reference Guide for SmartZone 3.4, 800-71175-001 Rev A
ruckusSCGPmipLMAFailOverTrap
ruckusSCGEventTraps (RUCKUS-EVENT-MIB)
.1.3.6.1.4.1.25053.2.10.1.705
Major
ruckusSCGEventSeverity
ruckusSCGEventType
ruckusSCGLMAIp
ruckusSCGEventMacAddr
ruckusSCGEventNodeMgmtIp
ruckusSCGEventCode
Triggered by LMA failover event. The event severity, event type, LMA IP
address, controller node MAC IP address, management IP address and
event code are displayed.
5008:lmaFailOver
ruckusSCGPmipBindingFailureTrap
ruckusSCGEventTraps (RUCKUS-EVENT-MIB)
.1.3.6.1.4.1.25053.2.10.1.706
Major
ruckusSCGEventSeverity
ruckusSCGEventType
ruckusSCGEventMacAddr
ruckusSCGEventNodeMgmtIp
ruckusSCGEventCode
Triggered by MN binding failure from LMA server event. The event
severity, event type, controller node MAC IP address, management IP
address and event code are displayed.
Ruckus Event MIB
Ruckus Event Trap
257