12 Test / Diagnostics

The test diagnostics function is available from the main operating screen.
This option allows the functionality of the system to be verified, and basic
trouble-shooting to be performed. In this mode, the amber LED will flash to
indicate that the system is in maintenance mode. The system will continue to
monitor any limits that are active and the Lifting Mode (if active) will continue
to monitor machine safety status. Alarm conditions and warnings / controls will be issued
as normal.
Relay / LED test
Beacon, Alarms
and LED test
Display options
The image shown is an example only. The exact contents of the sensor list will depend
on machine type and PME specification.
12.1 Relay Function Test
562200-000, Issue 1.2, December 2015
Equipment sensor angle
To test the relays and motion cut valves use the blue arrow to
highlight the appropriate output. When highlighted no motion for
that service should be possible.
Input signals are indicated by the LED lamp status.
System
information
Code protected
access to super-
visor features
Exit to previous menu
Operate / show status
of feature
Exit to previous menu
50 of 62