9

Daily Checks

Display - check for damage and correct operation
Safety Controller - check for damage and correct operation
Sensors and sensor cabling - check for damage
Cable Connections - check for damage, loose or disconnected connectors
Internal / external alarm (if fitted) and beacon (if fitted) functionality
See section 11 for test / diagnosis features.
If an issue is discovered which cannot be rectified using this guide, halt any operation,
seek authorised service immediately and do not continue operation until the fault has
been remedied.

10 Repair

Once a repair has been carried out and tested, the following must be checked:
Required Checks
Angles Check
Relay Check
Internal / external Alarm, LED and Beacon Check
Maintenance review

11 Test / Diagnostics

The test diagnostics function is available from the main operating screen.
This option allows the functionality of the system to be verified, and basic trou-
ble-shooting to be performed. In this mode, the amber LED will flash to indi-
cate that the system is in maintenance mode. The system will continue to
monitor any limits that are active and the Lifting Mode (if active) will continue
to monitor machine safety status. Alarm conditions and warnings / controls will be issued
as normal.
Relay / LED test
Beacon, Alarms
and LED test
Display options
The image shown is an example only. The exact contents of the sensor list will depend
on machine type and PME specification.
562100-000, Issue1.1, December 2015
Equipment sensor angle
Section
11.2
11.1
11.3
16.1
System
information
Code protected
access to super-
visor features
Exit to previous menu
23 of 36