8.2.3 Max Radius Limit Setting - Using Current furthest Point
Move equipment to required max
radius limit and press this button
To set the max radius limit using
the machine, move the equipment
to the desired radius, and press
the 'current farthest point' button.
A confirmation box will appear re-
porting the radius set. Press the
TICK button to continue.
that the limit activates at the set point. A limit cannot be deactivated when
close to or at the limit. Observe the operational limitations given in section 4.
562200-000, Issue 1.2, December 2015
Set the limit using the current furthest point of the
machine. Ensure the equipment is off the ground be-
fore setting the limit.
Once a limit is set, the internal alarm will sound and the RED LED
will light if the equipment reaches the current limit. Always check