8.1.3 Height Limit Setting - Using Current Highest Point

Move equipment to required
height limit and press this button
To set the height limit using the
machine, move the equipment to
the desired maximum height, and
press the 'current highest point'
button. A confirmation box will
appear reporting the height set.
Press the TICK button to continue.
that the current limit activates at the set point. The restriction cannot be de-
activated if in the alarm state. Observe the operational limitations given in
section 4.
562200-000, Issue 1.2, December 2015
Set the limit using the current highest point of the
machine. Ensure the tool is off the ground before
setting the limit.
Once a limit is set, the internal alarm will sound and the RED LED
will light if the equipment exceeds the current limit. Always check
30 of 62