9
System Messages

9.1 On Screen Messages

Close to max height
Max height reached
Close to max radius
Max radius reached
Close to min radius
Min radius reached
Close to min height
Min height reached
Close to SWL
Overload
Hydraulic Limit
In Override
*The approach limit is configurable at point of calibration, check system operation before
commencing work.
PME continuously monitors the presence and condition of the safety controller and sen-
sors. If the safety controller or any sensor fails an error message box will appear at the
bottom of the display. In the event of a failure, the cab mounted beacon (if fitted) will indi-
cate that the system is NOT active, the display red LED will flash and the internal and ex-
ternal alarms will sound.
562200-000, Issue 1.2, December 2015
Highest point of equipment within *0.5m of set limit
Equipment has reached set limit
Furthest point of equipment within *0.5m of set limit
Equipment has reached set limit
Nearest point of equipment within *0.5m of set limit
Equipment has reached set limit
Lowest point of equipment within *0.5m of set limit
Equipment has reached set limit
95 percent of the maximum safe working load
105 percent of the maximum safe working load
Pressure in the lift rams is in excess of 87% of main
relief valve pressure
Override has been activated (Soft or master Key)