9. Troubleshooting and Error Message

Error Message
Problem
Exceed the zero range
ERR0
ERR2
Exceed the initial zero point
Exceed
ERR3
range
ERR4
EEPROM failure
ERR5
Overload condition
Exceeds the display range
ERR6
Accumulated
ERR7
weighments
display range
Lower limit is higher than upper
ERR8
limit
ERR9
Exceed tare or pre-tare range
ERR10
Wrong calibration weights
(II)
the
A/D
resolution
number
exceeds
the
JWL
shootings
The item should be within 2% of full load
1. Check whether there are other alien
articles on the scale pan, remove those
articles.
2. LOAD CELL failure, which requires to be
changed or to contact our Service.
1. Check whether it is A/D failure, if yes,
please replace AD.
2. LOAD CELL failure, replacement
required or contact our Service.
Re-sold EEPROM or contact our Service.
Remove weight that is greater than the scale
capacity from the pan.
--------------------------------------------
of
Delete the exceeding weighments
re-act the upper limit setting and lower limit
setting
The tare value should be over zero and less
than or equal to full load.
Place the right weights( the calibration value
≤ full load)
is
14