Error Message; Problem & Solution - Jadever JCAII User Manual

Jadever jcaii counting scale user guide
Hide thumbs Also See for JCAII:
Table of Contents

Advertisement

8-12 Error message

=EEPROM can not be read
=The calibration range can not be read
=Zero point is too high
=Zero point is too low
=Unstable zero point
=Overload
=
The last accumulation is more than the preset accumulation allowed.
8-13 Problem & Solution
Printer can not print out
 Make sure the parameter P-05 is set correctly.
 Make sure the parameter P-06 and P-07 match the printer.
 If EZ-2P or BP-443D is being used, they should have download the printer format before.
HI & LO checking do not work
 Make sure the function is enabled.
 The value of LO is greater than HI.
No sound in HI & LO checking function
Make sure the parameter P-03 is set correctly.
Reset the time every time when the scale is turned on
Connect an optional RTC
How to check whether the printer is compatible to the scale
 Under the parameter P-05, select "normal" printer.
 Check the baud rate (P-06) and the data (P-07) is compatible to printer. If not, please change the
setting accordingly.
 Under the normal weighing mode, press
that this printer can replace the SH-24 printer.
to print. If the printer is able to print, it means
V03