RGBlink VSP 628PRO Quick Start Manual page 16

Hide thumbs Also See for VSP 628PRO:
Table of Contents

Advertisement

d. Turn the rotary knob, select <Receiving Card>, push the rotary knob to confirm. Turn the rotary knob again,
and select <Choose Cable>, push the rotary knob to confirm. Turn the rotary knob, select Port D and push the
rotary knob to confirm.
e. Turn the rotary knob, and select <Port Offset Y>, push the rotary knob to confirm. Turn the rotary knob,
Set Port Offset Y as 240 (Note: Port Offset Y = Vertical × Height, before we set vertical card as 2 and height
as 120). Shown as follows:
f. Turn the rotary knob, and select <Connect Type>, shown as follows:
Select the connection mode, the setting is same with Port U. Then connection of both the Port D and Port
U of One Sending Card to LED Screen is finished.
Rendering is as follows:
Address:S603-604 Weiye Building Torch Hi-Tech Industrial Development Zone Xiamen, Fujian Province, P.R.C
->Sending Card
Receiving Card
Sending Card
->Receiving Card
->Choose Cable
Horizontal Card
Vertical Card
Width
Height
Port Offset X
->Port Offset Y
Connect Type
Height
Port Offset X
Port Offset Y
->Connect Type
>>
>>
>>
>>
Port D
3
2
120
120
0
240
>>
120
0
240
>>
15
Tel: 00865925771197
Email: sales@rgblink.com
Fax: 00865925788216
http://www.rgblink.cn