Configuration
Ethernet Configuration
To change the IP settings for a device, double-click on the entry in the main window or right-click
on it and select Configuration.
Fig. 14
Ethernet configuration
Enter static IP settings as required, or select DHCP if using dynamic IP addressing.
You can add a name for the device in the Hostname field. Only characters a–z, A–Z, 0–9 and _
(underscore) are allowed.
The default password for changing IP settings is blank (no password). If a password has been set
for the device you must enter it to be able to change the settings.
To set a new password, check the Change password box and enter the current password in the
Password field, then enter the new password in the New password field.
Click on Set to save the new settings. The device will reboot automatically.