Note: If the value of parameter Screw Error Comp is modified, you need to import the target
compensation data again.
You can also export the imported compensation file to a USB flash disk for later use
by pressing F7 →F5.
5.8.2 Compensate Screw Error by Related Parameter Settings
This operation is used to compensate screw error by setting compensation
parameters about screw error in the software directly.
To compensate screw error by related parameters, do the following:
1.
To select the axis needed to compensate, press T / S / P.
2.
Do one of the following:
Press F3, and set the start position, interval and amount for
compensation.
Press F1 to insert a blank line, and set the start position.
Note: It is not allowed to insert several blank lines at the same time.
3.
To set unidirectional compensation, press ↑ / ↓ / ← / → to select the target
input box of Err Pos, press Enter, and input a value according to the actual
situation.
4.
Optional: If backlash is needed, press 1, 2 or 3 to set backlash for each axis.
5.
To save and validate the setting, press F6.
Return to the machine origin.

5.9 Execute Instant Calibration

This operation is used to automatically execute fixed calibration for several tools.
See
Execute Fixed Calibration
To execute instant calibration, do the following:
1.
To enter into Auto mode, press
SHANGHAI WEIHONG ELECTRONIC TECHNOLOGY CO., LTD
for details.
.