NEC NP-02HD Installation Manual page 67

Dlp cinema projector head/light module
Hide thumbs Also See for NP-02HD:
Table of Contents

Advertisement

WARNING
• The power supply unit handles large electrical currents. To maintain safety, use wires with the specifications as shown in the
following table, and affix to the terminals at the designated attachment torque.
• Always use solderless terminals with the dimensions as shown in the following diagram.
• The use of parts with dimensions other than as designated creates a risk of the AC power supply unit short circuiting due to
the terminal block generating heat and melting because the terminal block of the light power supply unit cannot be attached
correctly.
• Power supply terminal L, N (Black)
Thickness of compatible wiring
(using solderless terminal)
Solderless terminal dimensions
Tightening torque
Solderless terminal dimensions
Solderless terminal recommended
part (J.S.T parts)
J.S.T: J.S.T. Manufacturing Co. Ltd.
JIS
14mm
14mm
2
M5 x 10
2.0 to 2.5N·m
Max 12.2
Max 5.8
Unit: mm
Model R8-5
IEC/EN
UL
AWG6 or
2
AWG8
Min φ6.1
Min 4.5
When using AWG6: Model R14-5
When using AWG8: Model R8-5
Setting Up Your Projector
CSA
AWG6 or
AWG8
Min 1.0
-Max 2.0
Min 1.0
-Max 2.0
67