System Connection - Renishaw TONiC T103 Series Installation Manual

Linear encoder system
Table of Contents

Advertisement

System connection

Approved ESD precautions must be followed at
all times during readhead and interface electrical
connections. The readhead is connected to the
Ti / TD interface via a small, rugged connector to
allow for easy feed-through during installation.
Connecting the readhead
1
Remove the cover plate as shown
(2 × M2.5 hex head screws).
2
Taking care not to touch the pins, plug the
connector into the socket in the interface,
ensuring correct orientation as shown.
3
Refit the cover plate ensuring the cable ferrule is located in the recess on the inside and no wires are trapped under the cover plate.
TONiC RKLC20-S linear installation guide
Disconnecting the readhead
1
Remove the cover plate on the interface
(2 × M2.5 hex head screws).
2
Gently lever the connector PCB
(on the end of the cable) out of the socket.
Do not pull the cable to remove
the connector.
3
Place the connector in an anti-static bag.
4
Refit the cover plate.
9