Tonic Quick-Start Guide - Renishaw TONiC T103 Series Installation Manual

Linear encoder system
Table of Contents

Advertisement

If a reference mark is not being used, the calibration routine should now be
exited by pressing and releasing the CAL button. The CAL LED will stop flashing.
NOTE: If calibration fails, restore factory defaults by pressing and holding the CAL button whilst switching on.
TONiC RKLC20-S linear installation guide
This section is a quick-start guide to installing a TONiC system.
More detailed information on installing the system is contained on
Ensure scale, readhead optical window and mounting faces are clean and free from obstructions.
If required, ensure reference mark selector magnet is correctly positioned.
Plug the readhead cable into the Ti / TD interface under the cover plate and reassemble interface.
Ensure AGC is switched off - the CAL LED on the readhead should be off (if not press and hold the
CAL button on the interface until the CAL LED on the readhead switches off).
Install and align the readhead to maximise signal strength over the full axis travel as indicated by the
readhead and interface set-up LEDs (readhead - Green; interface - ideally Blue / Purple).
Press and release the CAL button on the interface.
The CAL LED on the readhead will be single flashing.
Move the readhead along the scale at slow speed (<100 mm/s),
without passing a reference mark, until the CAL LED starts double flashing.
No reference mark
(Incremental CAL values are automatically stored)
The system is now calibrated and ready for use. AGC can now be switched on if required by pressing and holding the CAL button until
the CAL LED on the readhead switches on. CAL values and AGC status are stored in readhead non-volatile memory at power down.

TONiC quick-start guide

page 10
and
page 11
of this installation guide.
INSTALLATION
(See 'RKLC20-S scale installation
drawing').
Connect to receiving electronics and power-up.
CALIBRATION
Move the readhead back and forth over the selected reference mark
until the CAL LED stops flashing and remains 'off'.
(Incremental and reference mark CAL values are automatically stored)
page
9,
Reference mark
(See page
11). Repeat the installation and calibration routine.