Load Sensing Controls; Ls Control With Bleed Orifice (Do Not Use With Pvg Valves); Integral Pc Function; Load Sensing System Characteristics - Danfoss PVG 16 Service Manual

Proportional valves
Hide thumbs Also See for PVG 16:
Table of Contents

Advertisement

Service Manual
PVG 16 and 32 Service Assembly/Disassembly Guide
General information

Load sensing controls

8 |
©
Danfoss | November 2017
The LS control matches system requirements for both pressure and flow in the circuit regardless of the
working pressure. Used with a closed center control valve, the pump remains in low-pressure standby
mode with zero flow until the valve is opened. The LS setting determines standby pressure.
Typical operating curve
Q max
0
0
Pressure
Most load sensing systems use parallel, closed center, control valves with special porting that allows the
highest work function pressure (LS signal) to feed back to the LS control.
Margin pressure is the difference between system pressure and the LS signal pressure. The LS control
monitors margin pressure to read system demand. A drop in margin pressure means the system needs
more flow. A rise in margin pressure tells the LS control to decrease flow.

LS control with bleed orifice (do not use with PVG valves)

The load sense signal line requires a bleed orifice to prevent high-pressure lockup of the pump control.
Most load-sensing control valves include this orifice. An optional internal bleed orifice is available, for use
with control valves that do not internally bleed the LS signal to tank.

Integral PC function

The LS control also performs as a PC control, decreasing pump flow when system pressure reaches the PC
setting. The pressure compensating function has priority over the load sensing function.
For additional system protection, install a relief valve in the pump outlet line.

Load sensing system characteristics:

Variable pressure and flow
Low pressure standby mode when flow is not needed
System flow adjusted to meet system requirements
Lower torque requirements during engine start-up
Single pump can supply flow and regulate pressure for multiple circuits
Quick response to system flow and pressure requirements
Load sensing circuit
P101 968E
P101 967
L1104530 | AX00000133en-US0106