Verttlc8tton/nemeay
Engine stops.
5. Emergency STOP
5.
Check operation of switch
(cont.)
switch or STOP SWITch
WITh an ohmmeter.
in panel defective,
opening fuel run
solenoid circuIT.
6.
Switches and/or wiring.
6.
Inspect all wiring for
short circuits and loose
connections. Inspect
switches for proper
operation.
-
Battery not charging.
1.
A~ernator
D.C.
1 a. Check drive
be~
tension.
Be sure
a~ernator
turns
freely.
1 b. Check for loose connections.
1 c. Check output WITh
vo~meter.
1 d. Ensure 12 Volts are present
at the R terminal
Battery runs down.
1. Oil pressure switch.
1. Observe
if
gauges and
panel lights are activated
when engine is not running.
Test the oil pressure switch.
2. High resistance leak
2. Check wiring. Insert
to ground.
sensitive (0-.25 Amp) meter
in battery lines. (Do not
start engine.) Remove
connections and replace
after short is located.
3. Low resistance leak.
3. Check all wires for
temperature rise to locate
the
fau~.
4.
Alternator.
4.
Disconnect alternator at
output, after a good battery
charging. If leakage stops,
remove
a~ernator
and
bench test.
Repair or replace.