Btda System Specifications - Westerbeke BTDA 15.0 Operator's Manual & Installation Manual

Marine diesel generator set
Table of Contents

Advertisement

15.0 KW BTDA System Specifications (continued)
Tune-up Specifications
Injector Pressure
Engine Timing
Governor
Generator Compartment
Ambient Temperature
1920
+
71 - 0 psi (135
+
5 - 0 kg/cm2)
Static timed - drop valve method
0.180
± .005 inches BTDC
or
0° T.O.C. #1 cylinder.
1 mm of cam lift using measuring device for
injection pump.
Hydraulic mechanical type in the injection pump
104° F (40" C) Maximum
NOTE:
Forced ventilation should be provided as needed to maintain
generator compartment ambient temperature below 104° F.
Westerbeke Generators
16
15.0KW BTDA