Chapter 2 Creation and Execution of a User Program

2.6 Settings on the Inverter

The easy sequence function is a feature of the SJ700 Series Inverter. The easy sequence function
enables the inverter to access the variables written in a user program via inverter input/output terminals.
Programming software EzSQ provides the reserved variables for control access to the inverter via
external terminals. You can combine these variables as required to control inverter operation.
Some reserved variables require the inverter settings to enable the variables. Also, the settings of
frequency commands, operation commands, and input/output terminals on the inverter must follow those
specified in the user program.
The table below lists the items, reserved variables, and function codes that must be configured when
using the easy sequence function. For details on the reserved variables, see the explanation of settings
related to the easy sequence function in Chapter 5.
Category
Operation
Selection of easy sequence function
switching
Program run signal
General-purpose input
contacts (8 contacts)
General-purpose
output contacts (6
contacts)
Input/
output
switching
General-purpose
analog inputs
(3 terminals)
General-purpose
analog outputs
(3 terminals)
Frequency source setting
Command
Run command source setting
switching
Accel/decal time input selection
Other
User-defined variables (32 variables)
Item
Terminal name
PRG (FW terminal)
Intelligent input
terminals 1 to 8
Intelligent output
terminals 11 to 15
Intelligent relay output
terminals AL0 to AL2
O terminal
OI terminal
O2 terminal
FM terminal
AM terminal
AMI terminal
2 - 4
Variable notation
Related function
in program
code
-
A017
-
A017
X (00) to X (07)
C001 to C008
Xw
C021 to C025
Y (00) to Y (05)
Yw
C026
XA (0)
XA (1)
XA (2)
YA (0)
C027
YA (1)
C028
YA (2)
C029
SET-Freq
A001
FW, RV
A002
STA, STP, F/R
ACCEL
P031
DECEL
U (00) to U (31)
P100 to P131
Variable/terminal use
condition
-
The PRG terminal is
enabled when A017 = 01.
(The FW function is
disabled.)
Function code settings are
required.
-
-
No setting is required.
-
Function code settings are
required.
Related variables are valid
only when A001 = 07.
Related variables are valid
only when A002 = 01.
Related variables are valid
only when P031 = 03.
The variables can be
redefined by using the
digital operator or EzSQ.