(3) B parameters
Display
Function name
code
b130 Overvoltage suppression enable
b131 Overvoltage suppression level
Acceleration and deceleration
b132
rate at overvoltage suppression
Overvoltage suppression
b133
propotional gain
Overvoltage suppression
b134
Integral time
*3
Display
Inverter
code
capacity
Under 55(kW)
b022/b025
75 to 132(kW)
Over 160(kW)
*4
Display
Inverter
code
capacity
Under 55(kW)
b041 to b044
75 to 132(kW)
Over 160(kW)
*5
Display
Inverter
code
capacity
Under 55(kW)
b083
75 to 132(kW)
Over 160(kW)
*6
Display
Inverter
code
capacity
Under 55(kW)
b126
75 to 132(kW)
Over 160(kW)
Range of setting
0 (disabling the restraint), 1 (controlled deceleration),
2 (enabling acceleration)
200V class: 330 to 390
400V class: 660 to 780
10 to 3000
0 to 255
0 to 65535
Setting range
20 to 2000
20 to 1800
20 to 1800
Setting range
0 to 200/255(no)
0 to 180/255(no)
0 to 180/255(no)
Setting range
5 to 150
5 to 100
5 to 30
Setting range
0 to 2000
0 to 1800
0 to 1800
8 - 8
Minimum
Setting during
Updating during
operation
operation
unit
(allowed or not)
(allowed or not)
×
×
1 (V)
×
0.01 (s)
0.01(s)