Variable name
Rotation direction
Dir
monitoring
- Explanation
This variable can be used to monitor the direction of motor operation by the inverter. The data
monitored with this variable corresponds to the data monitored by the rotation direction monitoring
function (d003). This variable is read-only.
- Sample program: Program to output the output frequency data to a general-purpose analog output
while operating the motor for reverse rotation at 60 Hz and forward rotation at 60 Hz
:
U(00)=
LOOP
U(01)=
UL(01)=
UL(01)=
UL(01)=
select
case
UL(00)=
case
UL(00)=
case else
UL(00)=
end select
YA(1)=
goto
LOOP
:
Range of values
0: Stop
1: Forward rotation
2: Reverse rotation
5000
Dir
FM
UL(01) *
5000
UL(01) /
6000
U(01)
1
U(00)
+
UL(01)
2
U(00)
-
UL(01)
U(00)
UL(00)
Chapter 5 Instruction Words
Default
Unit
-
-
: Set the offset data.
: Fetch the operation direction data.
: Fetch the output frequency data.
: Convert the scale to 0% to 50%.
: When the inverter operates the motor for
forward rotation
: When the inverter operates the motor for
reverse rotation
: When the motor is stopped
: Output the data to an analog output (AM
terminal).
5 - 39
Data size
Attribute
Unsigned
Readable
1-word data