8.1 Inverter Parameters and Available Settings

The tables below list the parameters and ranges of settings available for updating with the chg param
instruction.
(1) F parameters
Display
Function name
code
F001
Output frequency setting
F002
Acceleration (1) time setting
Acceleration (1) time setting,
F202
2nd motor
Acceleration (1) time setting,
F302
3rd motor
F003
Deceleration (1) time setting
Deceleration (1) time setting,
F203
2nd motor
Deceleration (1) time setting,
F303
3rd motor
F004
Keypad Run key routing
(2) A parameters
Display
Function name
code
A001 Frequency source setting
A002 Run command source setting
A003 Base frequency setting
Base frequency setting, 2nd
A203
motor
Base frequency setting, 3rd
A303
motor
A004 Maximum frequency setting
Maximum frequency setting,
A204
2nd motor
Maximum frequency setting,
A304
3rd motor
A005 [AT] selection
A006 [O2] selection
[O]-[L] input active range start
A011
frequency
[O]-[L] input active range end
A012
frequency
[O]-[L] input active range start
A013
voltage
[O]-[L] input active range end
A014
voltage
[O]-[L] input start frequency
A015
enable
External frequency filter time
A016
const.
Easy-sequence function
A017
selection
A019 Multispeed operation selection
A020 Multistage frequency setting
Multistage frequency setting,
A220
2nd motor
Multistage frequency setting,
A320
3rd motor
Range of setting
Do not use
1 to 360000
1 to 360000
1 to 360000
1 to 360000
1 to 360000
1 to 360000
0 (forward rotation), 1 (reverse rotation)
Range of setting
0 (keypad potentiometer), 1 (control circuit terminal block),
2 (digital operator), 3 (RS485), 4 (option 1), 5 (option 2),
6 (pulse-string input), 7 (easy sequence),
10 (operation function result)
1 (control circuit terminal block), 2 (digital operator),
3 (RS485), 4 (option 1), 5 (option 2)
30 to "maximum frequency "
30 to "maximum frequency, 2nd motor"
30 to "maximum frequency, 3rd motor"
30 to 400
30 to 400
30 to 400
0 (switching between O and OI terminals), 1 (switching
between O and O2 terminals), 2 (switching between O
terminal and keypad potentiometer), 3 (switching between
OI terminal and keypad potentiometer), 4 (switching
between O2 and keypad potentiometer)
0 (single), 1 (auxiliary frequency input via O and OI
terminals) (nonreversible), 2 (auxiliary frequency input via
O and OI terminals) (reversible), 3 (disabling O2 terminal)
0 to 40000
0 to 40000
0. to "[O]-[L] input active range end voltage"
"[O]-[L] input active range start voltage" to 100
00 (external start frequency), 01 (0 Hz)
1. to 30. or 31 (500 ms filter ±0.1 Hz with hysteresis)
0 (disabling), 1 (enabling)
0 (binary: 16 speeds selectable with 4 terminals), 1 (bit: 8
speeds selectable with 7 terminals)
0 to "maximum frequency"
0 to "maximum frequency, 2nd motor"
0 to "maximum frequency, 3rd motor"
8 - 1
Chapter 8 Appendix
Minimum
Setting during
Updating during
operation
operation
unit
(allowed or not)
(allowed or not)
0.01 (s)
0.01 (s)
0.01 (s)
0.01 (s)
0.01 (s)
0.01 (s)
×
×
Minimum
Setting during
Updating during
operation
operation
unit
(allowed or not)
(allowed or not)
×
×
×
×
×
×
1 (Hz)
×
×
1 (Hz)
×
×
1 (Hz)
×
×
1 (Hz)
×
×
1 (Hz)
×
×
1 (Hz)
×
×
×
×
×
0.01 (Hz)
×
0.01 (Hz)
×
1 (%)
×
1 (%)
×
×
×
×
×
×
0.01 (Hz)
0.01 (Hz)
0.01 (Hz)

Advertisement