Chapter 8 Appendix
(4) C parameters
Display
Function name
code
C134 Output 13 on-delay time
C135 Output 13 off-delay time
C136 Output 14 on-delay time
C137 Output 14 off-delay time
C138 Output 15 on-delay time
C139 Output 15 off-delay time
C140 Output RY on-delay time
C141 Output RY off-delay time
C142 Logical output signal 1 selection 1
C143 Logical output signal 1 selection 2
Logical output signal 1 operator
C144
selection
C145 Logical output signal 2 selection 1
C146 Logical output signal 2 selection 2
Logical output signal 2 operator
C147
selection
C148 Logical output signal 3 selection 1
C149 Logical output signal 3 selection 2
Logical output signal 3 operator
C150
selection
C151 Logical output signal 4 selection 1
C152 Logical output signal 4 selection 2
Logical output signal 4 operator
C153
selection
C154 Logical output signal 5 selection 1
C155 Logical output signal 5 selection 2
Logical output signal 5 operator
C156
selection
C157 Logical output signal 6 selection 1
C158 Logical output signal 6 selection 2
Logical output signal 6 operator
C159
selection
Input terminal response time
C160
setting 1
Input terminal response time
C161
setting 2
Input terminal response time
C162
setting 3
Input terminal response time
C163
setting 4
Input terminal response time
C164
setting 5
Input terminal response time
C165
setting 6
Input terminal response time
C166
setting 7
Input terminal response time
C167
setting 8
Input terminal response time
C168
setting FW
Multistage speed/position
C169
determination time
Range of setting
0 to 1000
0 to 1000
0 to 1000
0 to 1000
0 to 1000
0 to 1000
0 to 1000
0 to 1000
Same as the settings of C021 to C026
(except those of LOG1 to LOG6)
Same as the settings of C021 to C026
(except those of LOG1 to LOG6)
0 (AND), 1 (OR), 2 (XOR)
Same as the settings of C021 to C026
(except those of LOG1 to LOG6)
Same as the settings of C021 to C026
(except those of LOG1 to LOG6)
0 (AND), 1 (OR), 2 (XOR)
Same as the settings of C021 to C026
(except those of LOG1 to LOG6)
Same as the settings of C021 to C026
(except those of LOG1 to LOG6)
0 (AND), 1 (OR), 2 (XOR)
Same as the settings of C021 to C026
(except those of LOG1 to LOG6)
Same as the settings of C021 to C026
(except those of LOG1 to LOG6)
0 (AND), 1 (OR), 2 (XOR)
Same as the settings of C021 to C026
(except those of LOG1 to LOG6)
Same as the settings of C021 to C026
(except those of LOG1 to LOG6)
0 (AND), 1 (OR), 2 (XOR)
Same as the settings of C021 to C026
(except those of LOG1 to LOG6)
Same as the settings of C021 to C026
(except those of LOG1 to LOG6)
0 (AND), 1 (OR), 2 (XOR)
0 to 200
0 to 200
0 to 200
0 to 200
0 to 200
0 to 200
0 to 200
0 to 200
0 to 200.
0 to 200
8 - 12
Minimum
Setting during
Updating during
operation
operation
unit
(allowed or not)
(allowed or not)
×
0.1 (s)
×
0.1 (s)
×
0.1 (s)
×
0.1 (s)
×
0.1 (s)
×
0.1 (s)
×
0.1 (s)
×
0.1 (s)
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×2(ms)
×
×2(ms)
×
×2(ms)
×
×2(ms)
×
×2(ms)
×
×2(ms)
×
×2(ms)
×
×2(ms)
×
×2(ms)
×
×10(ms)
×