- Sample program: Program to make the inverter alternately repeat forward rotation of the motor at 60
Hz and reverse rotation of the motor at 10 Hz
  :
U(00)=
ACCEL=
DECEL=
LOOP
SET-Freq=
FW=
wait
delay off
  :
wait
delay on
SET-Freq=
  :
wait
RV=
Wait
goto
  :
- Example of operation (timing chart)
TC (0)
Comparison
for matching
TD (0)
Y (00)
delay on Y (00) TD (0) 1000
Timing chart for operation using the delay on and delay off instructions
1000
1000
1000
6000
1
RUN
=
1
FW
TD(0)
15.00
RUN
=
0
RV
TD(0)
1.00
1000
FM
=
U(00)
0
RUN
=
0
LOOP
2^31-1
1000
Chapter 5 Instruction Words
: The output frequency for reverse rotation is 10 Hz.
: Set the acceleration time to 10 seconds.
: Set the deceleration time to 10 seconds.
: Accelerate the forward rotation speed up to 60 Hz.
: Wait until the motor operates at 60 Hz.
: Start the 15-second timer counter.
: Turn the FW terminal off after 15 seconds elapse.
: Wait until the motor stops.
: Start reverse rotation after 1 second elapses.
: Accelerate the reverse rotation speed up to 10 Hz.
: Wait until the output frequency reaches 10 Hz.
: Decelerate and stop the motor.
: Wait until the motor stops.
1500
delay off Y (00) TD (0) 1500
5 - 23
2^31-1
timer off TD (0)