Selection example of wires
To comply with UL 1004-1 and CSA-C22.2 No. 100, use UL certified 75 ˚C rated copper wires for wiring.
The following table shows the 75 ˚C rated wire size [AWG] , which is used for wiring of TM-RFM, TM-RG2M, and TM-RU2M
series.
■TM-RFM SERIES
Direct drive motor
TM-RFM002C20
TM-RFM004C20
TM-RFM006C20
TM-RFM006E20
TM-RFM012E20
TM-RFM018E20
TM-RFM012G20
TM-RFM048G20
TM-RFM072G20
TM-RFM040J10
TM-RFM120J10
*1 To comply with UL 508A and NFPA 79, wire size of AWG 14 or larger is required.
■TM-RG2M series and TM-RU2M series
Direct drive motor
TM-RG2M002C30
TM-RU2M002C30
TM-RG2M004E30
TM-RU2M004E30
TM-RG2M009G30
TM-RU2M009G30
*1 To comply with UL 508A and NFPA 79, wire size of AWG 14 or larger is required.
Wire [AWG]
U/V/W/
*1
16
12
*1
16
12
Wire [AWG]
U/V/W/
*1
18
9 COMPLIANCE WITH EACH REGION
9.2 Compliance with UL/CSA standard
9