2.5

Head Movement Monitoring and Control

The scanner is equipped with various switches that monitor and control head movement.
Table 15 lists and describes the switches.
Table. 15.
Switch
Preset
Limit (forward and reverse)
Crash (forward and reverse)
SCANNER STOP
Preset, limit, and crash switches are mounted to the upper and lower head carriage tracks
(see Figure 58 and Figure 59). Switches are triggered by magnets mounted in the upper
and lower carriages. These switches can be moved by loosening the locking set screw, and
sliding to a new location.
Head Movement Monitoring and Control Switches
Function
Provides a permanent fixed reference to the motor controller software to monitor
the head position relative to encoder counts. Identifies approximate mid-beam
position of head movement
Indicates that the head has reached the configured horizontal-movement limit
Stops all scanning and alerts the computer that a head has reached a hard stop
This is an operator push button that will disable the scanning motor controller and
any active sensors, for example, basis weight shutters will close, lasers will turn off
Fig. 58.
6510020335
Track Mounted Switches (limit, crash, and preset)
SCANNER SAFETY AND LOCAL CONTROLS