6.7.2

Scanner Status Information

The scanner status information section lists the scanners and the current status of the
scanner. If the scanner is in single point mode or fixed-point mode, the scanner head
position is also displayed.
The units of the single point position are displayed along with the value. The default unit
measurement is bins. The head position units are configured on the profile setup display.
Scanner Status Modes
Measurement (Scanning) : Scanner is scanning in normal operating mode
measuring production data. The scanner remains in this mode while performing a
scanning mode background or standardize.
Measurement (Single Point): Scanner is at single point measuring in production
data.
Measurement (Fixed Point): Scanner is at fixed point measuring in production data.
Maintenance (Scan test): Scanner is in maintenance mode performing a scanner
test.
Maintenance (Building Profile Correction): Scanner is in maintenance mode
performing a profile correction operation.
Maintenance (Stability): Scanner is in maintenance mode performing a stability
operation on a sensor.
Maintenance (Background): Scanner is in maintenance mode performing a
background operation on a sensor.
Maintenance (Reference): Scanner is in maintenance mode performing a reference
operation on a sensor.
Maintenance (Sample): Scanner is in maintenance mode performing a sample
operation on a sensor.
Offsheet: Scanner is in offsheet and available for operation.
Offline (Unavailable): Scanner is in offsheet and is unavailable for operation.
6510020335
Scanner Sensor Status Information
Fig. 116.