Configure The 3410 Series Electronics; Initial Communication Connection Using Ethernet; Ethernet Initial Connection Material Checklist; Ethernet Initial Connection Steps - Emerson Daniel 3410 Series Retrofit Instructions

Gas ultrasonic electronics
Hide thumbs Also See for Daniel 3410 Series:
Table of Contents

Advertisement

6

Configure the 3410 Series Electronics

Topics covered in this chapter:
1.
2.
The basic instructions for setting up the directory and initializing communications are
contained in the following text. Refer to the 3410 Series Gas Ultrasonic Flow Meter
Installation Manual (P/N 3-9000-759, Section 4) for more detailed instructions. Use Daniel
MeterLink v1.10 or later to make a connection to the meter.
6.1
Initial communication connection using
Ethernet
6.1.1

Ethernet initial connection material checklist

The following materials and information are required:
6.1.2

Ethernet initial connection steps

1.
2.
3.
Daniel
Gas Ultrasonic 3410 Series Electronics

Initial communication connection using Ethernet

Initial communication connection using RS-232 Serial
Write the converted configuration file to the meter
Configure the meter using the Field Setup Wizard
Check all settings and wiring carefully.
Set up the Meter Directory, and start initial communication with the 3410 Series
electronics.
3410 Ethernet adapter cable (Daniel P/N 1-360-01-596)
Personal computer (PC) configured as follows:
-
Daniel MeterLink software installed (version 1.10 or later)
-
Ethernet LAN adapter
-
Configured to automatically obtain IP address (via DHCP)
Desired 3410 Series meter(s) communication configuration parameters:
-
IP address
-
Serial communication parameters such as baud rate and Modbus ID (if desired)
Power up the 3410 Series meter and wait two minutes for the meter to startup.
Ensure that the Ethernet DHCP server is enabled on the 3410 CPU Module by setting
DHCP switch to the ON position.
Plug the Ethernet adapter cable (P/N 1-360-01-596) into the meter CPU Module and
connect the RJ45 end into the PC Ethernet connector.