27.
28.
29.
30.
31.
Daniel
™
Gas Ultrasonic 3410 Series Electronics
Install a ground wire to the ground lug on the side of the upper enclosure.
Figure 5-19:
Transmitter electronics enclosure ground wire
Attach flex conduit to the conduit ports on the transmitter electronics enclosure.
Before applying power to the meter, ensure the atmosphere is proven safe using an
intrinsically safe gas detector.
WARNING!
EXPLOSION HAZARD
Do not apply power to the meter with the end caps removed unless you are in a non-
hazardous or explosive-free environment.
Failure to comply could result in death, serious injury and possible equipment damage.
Apply the sealing compound to the conduit seal fittings and allow to set in
accordance with manufacturer specifications.
Apply electrical power to the system and verify the field connections are working
correctly.
Do not install end caps until you configure the meter.
This completes the installation of the hardware associated with the 3410 Series
Electronics meter retrofit procedure.
Installing the 3410 Series Electronics
33