Emerson Daniel 3410 Series Retrofit Instructions page 25

Gas ultrasonic electronics
Hide thumbs Also See for Daniel 3410 Series:
Table of Contents

Advertisement

6.
7.
8.
9.
Daniel
Gas Ultrasonic 3410 Series Electronics
Figure 4-3:
Remove the Acquisition cable
Remove all the screws that hold the transducer wires in the terminal blocks that
attach the transducers to the Acquisition module.
a. Remove the screws from the ends of the two connectors.
b. Disconnect the connectors and remove each of the transducer wires from the
connector.
Loosen the cable glands on the base enclosure and pull all of the transducer cables
out of the base enclosure.
Unscrew the three screws holding the Acquisition module in the base enclosure and
remove the Acquisition module.
The four mounting bolts holding the enclosure cover to the meter body are sealed
with an RTV silicone adhesive/sealant.
Remove the RTV with a flat blade screwdriver or utility knife around the perimeter of
the recessed opening and the RTV eases the removal of the sealant.
a. Use the 7/16" socket wrench to remove the four mounting bolts.
Removing Mark III Electronics