TANDBERG C90 System Integrator Manual page 77

Hide thumbs Also See for C90:
Table of Contents

Advertisement

Codec C90
Contents
Introduction
Getting Started
Contents
Introduction
Getting started
The Call Log commands,
cont...
xCommand CallLog Received Delete
Delete log of received calls. If a logtag is given as argument, that specific call is deleted from the log. If not
logtag is give, the complete received calls list will be deleted.
Parameters: Required parameters are marked with (r):
LogTag: <0..2147483647>
Example:
xCommand CallLog Received Delete LogTag:126
*r DeleteResult (status=OK):
*r/end
xCommand CallLog Missed Delete
Delete log of missed calls. If a logtag is given as argument, that specific call is deleted from the log. If not
logtag is give, the complete missed calls list will be deleted.
Parameters: Required parameters are marked with (r):
LogTag: <0..2147483647>
Example:
xCommand CallLog Missed Delete LogTag:119
*r DeleteResult (status=OK):
*r/end
D14128.03—JULY 2009
Interfaces
About the API
xConfiguration
xConfiguration
Interfaces
About the API
xCommand
xStatus
xCommand
xCommand
xStatus
The Camera Control PiP command
xCommand CamCtrlPip
Can be used to show or hide a small window with the camera selfview, while adjusting the camera position for
instance. (If selfview isn't already shown)
Parameters: Required parameters are marked with (r):
Mode(r): <On/Off>
Example:
xCommand CamCtrlPip Mode: On
*r CamCtrlPipResult (status=OK):