Table 50: Power Management Timings; Figure 37: At Style Power Up Boot - Advantech SOM-5992 Design Manual

Com express, come type7
Hide thumbs Also See for SOM-5992:
Table of Contents

Advertisement

Figure 37 : AT Style Power Up Boot
G3
VCC_5V_SBY (To COMe)
(Optional)
95%
10%
VCC_12V (To COMe)
PWR_BTN# (To COMe)
(Optional)
SUS_S3# (From COMe)
VCC_5V, VCC3V
For Carrier Board use
(not needed by Module)
PWR_OK (To COMe)
Module Intermal Power Rails
SYS_RESET# (To COMe) (Optional)
CB_RESET# (From COMe)
Table 50 : Power Management Timings
Sym
T1
Power Button
T2
The power-on time is defined as the time from when PS_ON# is pulled low
to when the VCC_12V, VCC_5V and VCC_3V output.
T3
VCC_12V rise time from 10% to 95%
T4
PWR_OK delay
T5
PWR_OK rise time
T6
See Note 1
T7
Power-down warning
S0
T3
T1
T4
Description
123
T5
T6
Power Down
~
T7
~
Min
Max
16ms
500ms
0.1ms
20ms
100ms
10ms
1ms

Advertisement

Table of Contents
loading

Table of Contents