Operable flow range
Output signal
6
Nominal
Recommended
diameter
min./max. full scale value
(v ~ 0.310 m/s/
[mm]
[in]
[dm
150
6
20 to 600 m
200
8
35 to 1 100 m
Flow characteristic values in US units
Nominal
Recommended
diameter
min./max. full scale value
(v ~ 0.3/10 m/s
[in]
[mm]
[gal/min]
½
15
1.0 to 27
1
25
2.5 to 80
–
32
4 to 130
1 ½
40
7 to 190
2
50
10 to 300
–
65
16 to 500
3
80
24 to 800
4
100
40 to 1 250
–
125
60 to 1 950
6
150
90 to 2 650
8
200
155 to 4 850
To calculate the measuring range, use the Applicator sizing tool (® ä 37)
Recommended measuring range
"Flow limit" section (® ä 25)
Over 1000 : 1
Output
Current output
Current output
Resolution
Damping
Assignable measured
variables
flow
Full scale value current
output
(v ~ 2.5 m/s)
3
/min]
[dm
3
/h
150 m
3
/h
300 m
flow
Full scale value current
output
(v ~ 2.5 m/s)
[gal/min]
1 200
4-20 mA HART (passive)
< 1 µA
Adjustable:0.0 to 999 s
• Volume flow
• Mass flow
Proline Promag P 200
Factory settings
Pulse value
(~ 2 pulse/s)
3
/min]
[dm
3
]
3
3
/h
0.03 m
3
/h
0.05 m
3
Factory settings
Pulse value
(~ 2 pulse/s)
[gal]
6
0.05
18
0.2
30
0.2
50
0.5
75
0.5
130
1
200
2
300
2
450
5
600
5
10
Low flow cut off
(v ~ 0.04 m/s)
[dm
3
/min]
3
2.5 m
/h
5 m
3
/h
Low flow cut off
(v ~ 0.04 m/s)
[gal/min]
0.10
0.25
0.5
0.75
1.25
2
2.5
4
7
12
15