Measuring Tube Specification; Materials - Endress+Hauser Proline Promag P 200 Technical Information

Electromagnetic flow measuring system
Table of Contents

Advertisement

Measuring tube specification

Materials

30
Nominal diameter
[mm]
65
80
100
125
150
200
Nominal
diameter
EN
ASME
(DIN)
[mm]
[in]
[bar]
15
½
PN 40
Class 150
25
1
PN 40
Class 150
32
PN 40
40
1 ½
PN 40
Class 150
50
2
PN 40
Class 150
65
PN 16
80
3
PN 16
Class 150
100
4
PN 16
Class 150
125
PN 16
150
6
PN 16
Class 150
200
8
PN 10
Class 150
Transmitter housing
• Order code for "Housing", option C: aluminum coating AlSi10Mg
• Window material: glass
Transmitter cable entries
Order code for "Housing", option C "GT20 two-chamber, aluminum coating"
Electrical connection
Cable gland M20 × 1.5
Thread G ½"
via adapter
Thread NPT ½"
via adapter
Sensor housing
Aluminum coating AlSi10Mg
Measuring tubes
Stainless steel 1.4301/304 or 1.4306/304L; for flanges made of carbon steel with Al/Zn protective coating
[in]
Pressure rating
2 ½
Class 150
3
Class 150
4
Class 150
5
Class 150
6
Class 150
8
Class 150
Pressure rating
AS 2129 AS 4087
[psi]
[bar]
[bar]
Table E
Table E
PN 16
Type of protection
• Non-Ex
• Ex ia
• Ex ic
• Ex nA
• Ex tb
For non-Ex and Ex
(except for CSA Ex d/XP)
For non-Ex and Ex
Proline Promag P 200
ASME
[lbs]
27.6
32.0
52.9
95.9
Process connection internal diameter
JIS
PFA
[bar]
[mm]
[in]
20K
20K
23
0.91
20K
32
1.26
20K
36
1.42
10K
48
1.89
10K
63
2.48
10K
75
2.95
10K
101
3.98
10K
126
4.96
10K
154
6.06
10K
201
7.91
Material
Plastic
Nickel-plated brass
Nickel-plated brass
Endress+Hauser
PTFE
[mm]
[in]
15
0.59
26
1.02
35
1.38
41
1.61
52
2.05
67
2.64
80
3.15
104
4.09
129
5.08
156
6.14
202
7.95

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Proline Promag P 200 and is the answer not in the manual?

Questions and answers