Endress+Hauser
Liner: PFA
Nominal diameter
[mm]
[in]
25
1
32
40
1 ½
50
2
65
80
3
100
4
125
150
6
200
8
Liner: PTFE
Nominal diameter
[mm]
[in]
+25 °C (+77 °F)
15
½
25
1
32
40
1 ½
50
2
65
80
3
100
4
125
150
6
200
8
The diameter of the pipe and the flow rate determine the nominal diameter of the sensor. The optimum velocity
of flow is between 2 to 3 m/s (6.56 to 9.84 ft/s). Also match the velocity of flow (v) to the physical properties
of the fluid:
• v < 2 m/s (6.56 ft/s): for abrasive fluids (e.g. potter's clay, lime milk, ore slurry)
• v > 2 m/s (6.56 ft/s): for fluids producing buildup (e.g. wastewater sludges)
For an overview of the measuring range full scale values, see the "Measuring range" section (® ä 5)
• No pressure loss occurs if the sensor is installed in a pipe with the same nominal diameter.
• Pressure losses for configurations incorporating adapters according to DIN EN 545 (® ä 20)
• Never install the sensor on the pump suction side in order to avoid the risk of low pressure, and thus damage
to the liner.
• Furthermore, install pulse dampers if reciprocating, diaphragm or peristaltic pumps are used.
• For information on the liner's resistance to partial vacuum (® ä 25)
• For information on the measuring system's resistance to vibration and shock (® ä 22), (® ä 22)
Limit values for absolute pressure in [mbar] ([psi]) for fluid temperatures:
+25 °C (+77 °F)
+80 °C (+176 °F)
0 (0)
0 (0)
0 (0)
0 (0)
0 (0)
0 (0)
0 (0)
0 (0)
0 (0)
0 (0)
Limit values for absolute pressure in [mbar] ([psi]) for fluid temperatures:
+80 °C (+176 °F)
0 (0)
0 (0)
0 (0)
0 (0)
0 (0)
0 (0)
0 (0)
0 (0)
0 (0)
0 (0)
0 (0)
– (–)
0 (0)
– (–)
0 (0)
– (–)
135 (1.96)
– (–)
135 (1.96)
– (–)
200 (2.90)
– (–)
+100 to +180 °C (+212 to
+356 °F)
0 (0)
0 (0)
0 (0)
0 (0)
0 (0)
0 (0)
0 (0)
0 (0)
– (–)
0 (0)
– (–)
0 (0)
– (–)
0 (0)
– (–)
0 (0)
– (–)
0 (0)
– (–)
0 (0)
+100 °C (+212 °F)
+130 °C (+266 °F)
0 (0)
100 (1.45)
0 (0)
100 (1.45)
0 (0)
100 (1.45)
0 (0)
100 (1.45)
0 (0)
100 (1.45)
40 (0.58)
130 (1.89)
40 (0.58)
130 (1.89)
135 (1.96)
170 (2.47)
240 (3.48)
385 (5.58)
240 (3.48)
385 (5.58)
290 (4.21)
410 (5.95)