Input; Measured Variable; Measuring Range; Operable Flow Range - Endress+Hauser Proline Cubemass C 500 Technical Information

Coriolis flowmeter
Table of Contents

Advertisement

Measured variable

Measuring range

Operable flow range

12
Заказывайте на сайте: www.tinnova.ru/endress_hauser/ || Эл. почта: info@tinnova.ru

Input

Direct measured variables
• Mass flow
• Density
• Temperature
Calculated measured variables
• Volume flow
• Corrected volume flow
• Reference density
Measuring ranges for liquids
DN
[mm]
1
2
4
6
Measuring range for gases
The full scale value depends on the density and the sound velocity of the gas used and can be
calculated with the formula below:
= minimum (
· ρ
max(G)
max(F)
Maximum full scale value for gas [kg/h]
max(G)
Maximum full scale value for liquid [kg/h]
max(F)
< 
max(G)
max(F)
ρ
Gas density in [kg/m³] at operating conditions
G
x
Constant dependent on nominal diameter
c
Sound velocity (gas) [m/s]
G
d
Measuring tube internal diameter [m]
i
DN
[mm]
1
2
4
6
To calculate the measuring range, use the Applicator sizing tool →  106
Recommended measuring range
"Flow limit" section →  64
Over 1000 : 1.
Measuring range full scale values 
[in]
¹⁄₂₄
¹⁄₁₂
¹⁄₈
¹⁄₄
0 to 1 000
: x ; ρ
· c
· π/2 · (d
)
2
· 3600)
G
G
G
i
can never be greater than 
max(G)
[in]
¹⁄₂₄
¹⁄₁₂
¹⁄₈
¹⁄₄
Proline Cubemass C 500
min(F)
[kg/h]
[lb/min]
0 to 20
0 to 0.735
0 to 100
0 to 3.675
0 to 450
0 to 16.54
0 to 36.75
max(F)
x
[kg/m
3
]
20
20
20
20
Endress+Hauser