Alarms
The GC-Pro has built-in high and low set-point alarms for all of the sensor readings. Alarms are displayed and logged in the
TM
AgrowTouch
panel and are sent in an email alert by the GrowControl
Each alarm has a trigger point and a toggle to enable or disable the alarm.
High Air-Temperature Alarm will automatically disable the lighting output for the respective zone.
Touch Panel
The alarms settings are accessed under the "Data" menu from the Main menu.
Press "Alarms Settings" button to access
the alarms settings menu.
Software
The alarms settings are accessed via the "Alarms" tab. The software has several additional alarms for notification in the event
that a sensor is disconnected and if a digital input has been activated.
Software Alarms
The software has several additional alarms which can send an email or sms. Simply check "Enable" to activate the alarm.
Analog Sensor Failure: If one of the analog sensors (such as climate sensor or hydroponics transmitter) become
disconnected, the software will send an email alert.
Note: In the event one of the analog sensors becomes disconnected, the controls functions associated with that sensor will be
disabled.
Digital Input Alarms: Activates when the respective digital input (such as a door switch, leak sensor, etc.) is activated.
41
www.agrowtek.com
Select an alarm class to view its alarms
settings.
© 2013 Agrowtek Inc.
| 83 Ambrogio Dr Suite H Gurnee, IL 60031 | agrowtek@agrowtek.com
TM
software.
Note: If the alarm has a set point, enter
it before enabling the alarm.