Main Differences And Compatibilities With The Fr-F500J Series - Mitsubishi Electric FR-F700PJ Series Manual

Hide thumbs Also See for FR-F700PJ Series:
Table of Contents

Advertisement

Main differences and compatibilities
with the FR-F500J series
Item
V/F control
Control method
Automatic torque boost
Output frequency
0.5 to 120Hz
range
Pr. 0 Torque boost
FR-F520J-1.5K to 3.7K: 6%
FR-F540J-1.5K, 2.2K: 5%
Pr. 1 Maximum frequency
60Hz
Changed initial value
Pr. 88 PID action selection
20 (PID reverse action)
Turn the X14 signal ON to enable PID control.
Pr. 37 Speed display
0.1
H1(Pr. 503) Maintenance timer
Changed setting
H2(Pr. 504) Maintenance timer alarm output set time
increments
Time per increments: 1000h
H2(Pr. 504) Initial value: 87 (87000h)
(Example) To set 87000h, set H2 (Pr. 504) = "87."
Pr. 52 Control panel display data selection
1: Output current
Pr.54 FM terminal function selection
0: Output frequency (initial value),
1: Output current
Pr. 60 to Pr. 63 Input terminal function selection
5: STOP signal (start self-holding selection)
Changed setting value
6: MRS signal (output stop)
9: JOG signal (Jog operation selection)
10: RES signal (reset)
---: STR signal (reverse rotation command)
Pr. 73 Terminal 2 0 to 5V, 0 to 10V selection
0: 0 to 5V (initial value),
1: 0 to 10V
Pr. 98 Automatic torque boost selection
Deleted functions
Pr. 99 Motor primary resistance
Long wiring mode (setting value 10, 11 of Pr. 70)
84
FR-F500J
FR-F700PJ
V/F control
General-purpose magnetic flux vector control
Optimum excitation control
IPM motor control
0.2 to 400Hz
FR-F720PJ-1.5K to 3.7K: 4%
FR-F740PJ-1.5K, 2.2K: 4%
120Hz
Pr. 128 PID action selection
0 (PID control disabled)

Set Pr. 128
"0" to enable PID control. (An X14 signal
input is not required when X14 is unassigned.)
0.001
Pr. 503 Maintenance timer
Pr. 504 Maintenance timer alarm output set time
Time per increments: 100h
Initial value: 9999 (no function)
(Example) To set 87000h, set Pr. 504 = "870."
Pr. 52 DU/PU main display data selection
0/100: Output current (select with
1: Output frequency (initial value),
2: Output current
Pr. 178 to Pr. 182 Input terminal function selection
5: JOG signal (Jog operation selection)
6: None
24: MRS signal (output stop)
25: STOP signal (start self-holding selection)
61: STR signal (reverse rotation command)
62: RES signal (reset)
Pr. 73 Analog input selection
0: 0 to 10V,
1: 0 to 5V (initial value)
Replacement function (General-purpose magnetic flux
vector control)
(Pr. 80 Motor capacity)
(Pr. 90 Motor constant)
Setting unnecessary (setting values 10 and 11 of Pr. 240
are deleted)
)

Hide quick links:

Advertisement

Table of Contents
loading