DU/PU monitor change, cumulative
monitor clear
Pr.52 DU/PU main display data selection
Pr.170 Watt-hour meter clear
Pr.268 Monitor decimal digits selection
Pr.564 Operating time carrying-over times
Pr.891 Cumulative power monitor digit shifted times
The monitor to be displayed on the main screen of the operation
panel and parameter unit (FR-PU07) can be selected.
Types of
Increments
Monitor
Output
0.01Hz
frequency
Output current
0.01A
Output voltage
0.1V
Alarm display
Frequency
0.01Hz
setting
Converter
0.1V
output voltage
Regenerative
0.1%
brake duty
Electronic
thermal relay
0.1%
function load
factor
Output current
0.01A
peak value
Converter
output voltage
0.1V
peak value
Output power
0.01kW
Input terminal
status
Output terminal
status
Cumulative
energization
1h
time 
Reference
voltage output
Actual operation
1h
time , 
Motor load
0.1%
factor
Cumulative
0.01kWh
power 
Power saving
Variable
effect
according
to
Cumulative
saving power
parameters
PID set point
0.1%
PID measured
0.1%
value
PID deviation
0.1%
value
Inverter I/O
terminal
monitor
Motor thermal
0.1%
load factor
Inverter thermal
0.1%
load factor
PTC thermistor
0.01k
resistance
 Selected by the parameter unit (FR-PU07)
 The cumulative energization time and actual operation time are
accumulated from 0 to 65535 hours, then cleared, and accumulated
again from 0.
When the operation panel is used, up to 65.53 (65530h) is displayed as
1h=0.001 and then accumulated from 0.
 The actual operation time is not added up if the cumulative operation
time before power supply-off is less than 1h.
 When using the parameter unit (FR-PU07), "kW" is displayed.
 Since the panel display of the operation panel is 4 digits in length, the
monitor value of more than "9999" is displayed as "----".
38
When setting parameters, refer to the instruction manual (applied) and understand instructions.
Pr.54 FM terminal function selection
Pr.171 Operation hour meter clear
Pr.563 Energization time carrying-over times
Pr.52 setting
Pr.54
Full Scale
operation
(FM)
PU main
panel
Value
setting
monitor
LED
0/100
1
Pr.55
0/100
2
Pr.56
200V class: 400V
0/100
3
400V class: 800V
0/100

5
5
Pr.55
200V class: 400V

8
8
400V class: 800V
Brake duty set in

9
9
Pr. 30 and Pr. 70
Electronic
thermal relay

10
10
function
operation level

11
11
Pr.56
200V class: 400V

12
12
400V class: 800V
Rated inverter

14
14
power


20
21
23
24
24
200%
25
50
50
Inverter capacity
51
52
52
100%
53
53
100%
54
55
Thermal relay
61
61
operation level
(100%)
Thermal relay
62
62
operation level
(100%)
64
The cumulative power monitor value digit can be shifted to the right
by the number set in Pr. 891.
By setting "0" in Pr. 170, the cumulative power monitor can be
cleared.
You can check the numbers of cumulative energization time monitor
exceeded 65535h with Pr. 563 and the numbers of actual operation
time monitor exceeded 65535h with Pr. 564.
Writing "0" in Pr. 171 clears the actual operation time monitor.
Pr.268 setting
9999
(initial value)
0
1
When Pr. 52 is set to "100", the set frequency monitor is displayed
during a stop and the output frequency monitor is displayed during
operation. (LED of Hz flickers during stop and is lit during operation.)
operation/stop
Output
2
Output frequency
frequency
Output
current
Output
voltage
Fault
display
 The set frequency displayed indicates the frequency to be output when
the start command is ON. Different from the frequency setting displayed
Pr. 52
when
= "5", the value based on maximum/minimum frequency and
frequency jump is displayed.
55, 56
Terminal FM output monitor change
Pr.55 Frequency monitoring reference
Set the full scale value when monitoring the output from terminal FM.
Monitor
Frequency
Current
 For the applicable monitor names, refer to the description on Pr.52.
Description
No function
When 1 or 2 decimal places (0.1 increments or 0.01
increments) are monitored, the decimal places are
dropped and the monitor displays an integer value (1
increments).
The monitor value of 0.99 or less is displayed as 0.
When 2 decimal places (0.01 increments) are
monitored, the 0.01 decimal place is dropped and the
monitor displays the first decimal place (0.1
increments).
When the monitor display digit is originally in 1
increments, it is displayed unchanged in 1
increments.
Pr.52
0
100
During
During stop
Set frequency
Output current
Output voltage
Alarm display
Pr.56 Current monitoring reference
Reference parameter
Initial Value
Pr.55
Pr.56
Rated inverter current
Pulse speed(terminal FM)
2400
pulse/s
1440
pulse/s
Pr.55
Output frequency
400Hz
reference
Pr.56
500A
Output current
reference
During
running
Output
frequency
60Hz