Mitsubishi Electric FR-F700PJ Series Manual page 31

Hide thumbs Also See for FR-F700PJ Series:
Table of Contents

Advertisement

Func-
Parameter
tion
820
Speed control P gain 1
821
Speed control integral time 1
870
Speed detection hysteresis
872
Input phase loss protection selection
Regeneration avoidance operation
882
selection
Regeneration avoidance operation
883
level
Regeneration avoidance compensation
885
frequency limit value
886
Regeneration avoidance voltage gain
888
Free parameter 1
889
Free parameter 2
891
Cumulative power monitor digit shifted times
892
Load factor
Energy saving monitor reference (motor
893
capacity)
Control selection during commercial power-
894
supply operation
895
Power saving rate reference value
896
Power unit cost
897
Power saving monitor average time
898
Power saving cumulative monitor clear
899
Operation time rate (estimated value)
C0
FM terminal calibration
(900)

C2
Terminal 2 frequency setting bias
frequency
(902)

C3
Terminal 2 frequency setting bias
(902)

125
Terminal 2 frequency setting gain
frequency
(903)

C4
Terminal 2 frequency setting gain
(903)

C5
Terminal 4 frequency setting bias
frequency
(904)

C6
Terminal 4 frequency setting bias
(904)

126
Terminal 4 frequency setting gain
frequency
(905)

C7
Terminal 4 frequency setting gain
(905)

C22
Frequency setting voltage bias
frequency (built-in potentiometer)
(922)

C23
Frequency setting voltage bias (built-in
potentiometer)
(922)

C24
Frequency setting voltage gain
frequency (built-in potentiometer)
(923)

C25
Frequency setting voltage gain (built-in
potentiometer)
(923)

Name
Setting Range
0 to 1000%
0 to 20s
0 to 5Hz
0, 1
0 to 2
300 to 800V
0 to 30Hz, 9999
0 to 200%
0 to 9999
0 to 9999
0 to 4, 9999
30 to 150%
0.4 to 15kW
0 to 3
0, 1, 9999
0 to 500, 9999
0, 1 to 1000h, 9999
0, 1, 10, 9999
0 to 100%, 9999
0 to 400Hz
0 to 300%
0 to 400Hz
0 to 300%
0 to 400Hz
0 to 300%
0 to 400Hz
0 to 300%
0 to 400Hz
0 to 300%
0 to 400Hz
0 to 300%
Minimum
Refer
Initial
Setting
Value
Increments
Page
1%
25%
0.001s
0.333s
0.01Hz
0Hz
1
0
1
0
0.1V
400/780V

0.01Hz
6Hz
0.1%
100%
1
9999
1
9999
1
9999
0.1%
100%
Rated
0.01kW
inverter
capacity
1
0
1
9999
0.01
9999
1h
9999
1
9999
0.1%
9999
0.01Hz
0Hz
0.1%
0%
0.01Hz
60Hz
0.1%
100%
0.01Hz
0Hz
0.1%
20%
0.01Hz
60Hz
0.1%
100%
0.01Hz
0Hz
0.1%
0%
0.01Hz
60Hz
0.1%
100%
Customer
to
Setting
54
54
37
50
53
53
53
53
54
54
38
55
55
55
55
55
55
55
55
55
46
46
46
46
46
46
46
46
46
46
46
46
31

Hide quick links:

Advertisement

Table of Contents
loading