DURKOPP ADLER 827-M Operating Manual page 96

Hide thumbs Also See for 827-M:
Table of Contents

Advertisement

94
Code
Possible cause
3218
Remaining thread monitor
left and right
3223
Skip stitch detected
3224
Bobbin failed to rotate
6360
No valid data on external
EEprom (internal data
structures are not
compatible with the external
data storage device)
6361
No external EEprom
connected
6362
No valid data on internal
EEprom (internal data
structures are not
compatible with the
external data storage
device)
6363
No valid data on internal
and external EEprom
(software version is not
compatible with the internal
data storage device,
emergency operating
features only)
6364
No valid data on internal
EEprom and no external
EEprom connected
(the internal data structures
are not compatible with
the external data storage
device, emergency
operating features only)
6365
Internal EEprom defective
6366
Internal EEprom defective
and external data not valid
(emergency operating
features only)
Remedial action
• Change left and right bobbin
• Perform software update
• Connect machine ID
• Check machine ID connection
• Switch off the control, wait until
the LEDs are off and then
switch on again
• Perform software update
• Check machine ID connection
• Switch off the control, wait until
the LEDs are off and then
switch on again
• Perform software update
• Check machine ID connection
• Switch off the control, wait until
the LEDs are off and then
switch on again
• Perform software update
• Replace the control
• Replace the control
Operating Instructions 827/827-M - 01.0 - 02/2019
Troubleshooting

Advertisement

Table of Contents
loading

This manual is also suitable for:

827

Table of Contents